Enhancing sample transport efficiency using an infrared-heated sample introduction system for single particle inductively coupled plasma mass spectrometry
Abstract
dc:description.abstractSingle particle inductively coupled plasma mass spectrometry (spICPMS) is a powerful approach for characterizing nanoparticles, microplastics, and even individual cells. In theory, if only one particle is introduced into the plasma at a time, the corresponding signal would show the elemental composition of this particle. However, the sensitivity and detection limits of spICPMS are often constrained by the low transport efficiency (TE) of conventional sample introduction systems. Enhancing TE is critical for maximizing detection capability and minimizing sample consumption, particularly when working with valuable samples like cells. Total-consumption systems achieving 100% TE for spICPMS may be achieved using infrared (IR)-heated spray chambers. In this study, an IR-heated sample introduction system was developed for spICPMS, and multiple optimization strategies were systematically evaluated. The resulting sample introduction system was applied to the analysis of nanoparticles of different elements, as well as to the analysis of microplastics (MPs) and cells, to determine their elemental composition and their mass (and size) distribution. Samples included most common particle types for spICPMS, demonstrating that the IR-heated sample introduction system is versatile and reliable when performing spICPMS analysis. The optimization focused on improving analytical sensitivity and TE across a range of particle types, with performance compared against commercially available sample introduction systems. Total comsumption of nanoparticle suspension was achieved with various IR-heated sample introduction systems. For single-cell analysis of a Se-enriched certified reference material, the optimized IR-heated system achieved a cell TE of 47 ± 6%, exceeding that of a commercial single-cell introduction system (30 ± 3%). Detection limits of 100–120 ag per cell were obtained, and the Se mass per cell determined by scICPMS (65–68 fg cell-1) was consistent with estimation derived from the certified value (70 fg), confirming analytical accuracy. For MPs analysis, IR heating increased the number of detected events approximately 20-fold relative to a standard system for labeled and unlabeled 4.5 μm MPs. For 10-μm MPs, 12% TE resulted instead of 0.2% with a standard system, extending the practical upper size range.
Degree
thesis:*- Department dc:contributor.department
- Chemistry
- Grantor
- Queen's University at Kingston
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zhou, Zichao
- Advisor dc:contributor.supervisor
-
- Beauchemin, Diane
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Licence dc:rights.uri
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1974/36438