Evaluating the performance of low-rise residential buildings in the permafrost environments of Canada's Northwest Territories

Abstract

dc:description.abstract

The Arctic is warming at nearly four times the global average rate. This process is known as Arctic amplification. As air temperatures rise, subsurface permafrost temperatures across the Canadian Arctic are also rising. In Canada’s Northwest Territories (NWT), near-surface permafrost thaw has been estimated to cause an annual $51 million in damage to public infrastructure, with costs expected to increase under continued climate warming. With the realities of climate warming altering arctic landscapes, communities across Canada’s NWT rely on outdated building code standards to guide the design, construction, and maintenance of low-rise residential structures. This research adopts a comprehensive approach to evaluating the performance of northern housing, with site-specific data collected in Inuvik, NWT. Estimates of annual ground subsidence are determined for current and future soil profiles across Inuvik. Current subsidence estimates utilize ground temperature data sets sourced from monitoring projects in Inuvik, while predicted values rely on ground temperatures simulated in GeoStudio TEMP/W using the IPCC SSP5-8.5 high emission scenario for 2025 - 2080. Estimated ranges of total subsidence are then used in settlement scenarios to evaluate the performance of a Government of NWT residential building design, modeled in SkyCiv Structural 3D, against National Building Code of Canada (NBCC) and CSA: O86 requirements. To assess the current condition of residential housing across the NWT, visual inspections were conducted in Inuvik, and interviews were completed with housing managers and technical officers across the territory. Annual ground subsidence values range from 12 mm - 148 mm at monitoring sites across Inuvik, with projected subsidence values increasing to 177 mm by 2080. Structural modeling evaluates 11 scenarios against strength and deflection limits described in relevant codes. Failure in strength and deflection occurs in 36% and 55% of tests respectively. Inspections of residential buildings and interview findings identify building deficiencies, indicating that current home designs do not achieve high-performance standards required in Canada's Arctic climate. Recommendations are provided based on these findings to improve maintenance, serviceability, and design of residential structures in Inuvik.

Degree

thesis:*
Department dc:contributor.department
Civil Engineering
Grantor
Queen's University at Kingston
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Haley, Abigail (Susan)
Advisors dc:contributor.supervisor
  • Hoult, Neil
  • Devoie, Élise

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-ShareAlike 4.0 International
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/36907

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Haley, Abigail (Susan). Evaluating the performance of low-rise residential buildings in the permafrost environments of Canada's Northwest Territories. Queen's University at Kingston, 2026. https://hdl.handle.net/1974/36907