Queen's University at Kingston
Field Testing of Culverts: Curvature Measurement Technique for Profiled-Wall HDPE Pipe and Load Testing under Multiple Lane Loading
Abstract
dc:description.abstractAgeing buried flexible pipes must continue to carry load safely, yet visual inspection does not quantify the load effects that develop in the wall. This thesis applies distributed fibre optic strain sensing to an in-service corrugated steel culvert in the field and a profiled-wall high-density polyethylene (HDPE) pipe in the laboratory. Bonded optical fibres record the circumferential strain continuously around the wall, resolving the average strain and the curvature, and hence thrust and bending, rather than at discrete points. In the field study, the culvert was instrumented with three fibre optic loops across the loaded lane and subjected to known single- and two-truck loading. A second truck in the adjacent lane increased the peak compression by no more than 3 µε and reduced rather than increased the peak curvature; two-truck loading was therefore no more critical than single-truck loading. A hogging curvature developed just below the springlines under every arrangement, unexpected for a well-supported culvert and consistent with suspected undermined soil support. The laboratory study evaluated a strip method that provides a liner's wall curvature from its accessible inner surface, using a bonded low-density polyethylene (LDPE) strip on the profiled-wall pipe under parallel-plate compression, with fibres on the inner and outer surfaces as the reference. The strip overestimated this reference by 38.5% (annular) and 31% (modified helical) on average. Digital image correlation and a closed-form ring solution, both independent of the fibre data, confirmed the surface fibres as the accurate measure; the strip therefore overestimates the true wall curvature. The discrepancy is attributed to strain not varying linearly through the combined depth of the wall and the strip: a solid liner satisfies the strip method's assumption of linearity, but a profiled wall does not, its through-depth strain being non-linear, consistent with the documented behaviour of profiled-wall sections. The strip is thus accurate for solid liners but overestimates the curvature of the profiled-wall liner tested.
Degree
thesis:*- Department dc:contributor.department
- Civil Engineering
- Grantor
- Queen's University at Kingston
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Gladkiy, Sergey
- Advisors dc:contributor.supervisor
-
- Hoult, Neil
- Moore , Ian
Subjects
dc:subject × 4Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1974/36929