Back to search

Queens University

Defect Retention and Irradiation-Assisted Recovery in High-Purity Aluminum under Low-Dose Proton Irradiation

Abstract

dc:description.abstract

This thesis reviews the literature and presents a fundamental investigation of irradiation-induced defect evolution in 106 μm thick 99.997 at.% aluminum using low-dose proton irradiation to study defect retention, defect self-organization, and recrystallization. The study is divided into two phases. In Phase I, recrystallized foils were produced with a strong Cube texture by annealing at 803 K for 8 hours, providing a baseline microstructure. Proton irradiation experiments were designed from SRIM calculations and performed at low dpa levels using focused and defocused 4 MeV proton beams to examine whether measurable residual defects can persist despite the inherently high defect mobility of aluminum. A key experimental challenge was minimizing irradiation-induced thermal recovery by maintaining the lowest practical irradiation temperature. The baseline reference state, used for all comparisons, and irradiated samples were characterized using X-ray diffraction peak analysis, 78 K tensile testing, and electron microscopy to assess lattice strain, mechanical response, spatial heterogeneity, and defect structures. Focused-beam irradiation to 0.013 dpa reached an average temperature of 316 K and resulted in X-ray peak narrowing, while dislocation loops were observed by TEM. Focused-beam irradiation to 0.13 dpa reached 348 K and resulted in X-ray peak broadening and the presence of dislocation loops. The defocused 0.13 dpa exposure reached 404 K and showed peak narrowing, similar yield stress and Haasen slope, and dislocation loops. Phase II focuses on irradiation-assisted recrystallization kinetics. The same aluminum foils in the as-rolled state were irradiated using a defocused 4 MeV proton beam such that irradiation acted as a coupled source of heat and continuously generated point defects. To isolate irradiation effects, thermal-control experiments were conducted under matched temperature–time conditions. Irradiation-assisted recrystallization was evaluated using X-ray macrotexture measurements. Irradiation to 0.062 and 0.13 dpa over 774 and 1576 min reached mean temperatures of 583 and 555 K and resulted in Cube volume fractions of 30.4% and 32.4%, respectively, compared with 51.8% and 30.3% after the corresponding thermal-control treatments. This work provides insight into defect retention in aluminum at low irradiation doses and clarifies the role of irradiation as an energy input that can influence microstructural evolution.

Degree

thesis:*
Department dc:contributor.department
Mechanical and Materials Engineering
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Moradi, Marjan
Advisor dc:contributor.supervisor
  • Diak, Bradley J

Subjects

dc:subject × 3

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/36955

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Moradi, Marjan. Defect Retention and Irradiation-Assisted Recovery in High-Purity Aluminum under Low-Dose Proton Irradiation. 2026. https://hdl.handle.net/1974/36955