Out-Of-Plane Bending Of Masonry Walls With Near-Surface-Mounted And Externally-Bonded Corrosion-Resistant Reinforcement

Abstract

dc:description.abstract

Masonry walls subjected to out-of-plane loading, such as in a seismic event, require reinforcement to improve the ductility of the system. In current masonry construction practice, reinforcement is placed internally and fully grouted. For new construction this can make the wall unjustifiably heavy by not taking advantage of its light, hollow structure. For existing construction, it is difficult to retrofit using this technique. Additionally, the reinforcement is located close to the neutral axis which reduces its effectiveness. Fiber-Reinforced Polymer (FRP) bars, strips and sheets are becoming increasingly popular in construction applications due to their noncorrosive nature and ease of installation. Also, stainless steel bars are used where the structure is exposed to a corrosive environment but have not found wider application for masonry structures. This study is an experimental investigation of the structural performance of masonry walls reinforced with Near-Surface-Mounted (NSM) FRP and stainless steel reinforcement under out-of-plane bending. Additionally, walls with Externally Bonded (EB) FRP sheets were tested. The study simulates retrofitting applications and also proposes the NSM technique for new wall construction, using pre-grooved blocks, in lieu of the conventional method of internal reinforcing and grouting. To accommodate the NSM reinforcement, the grooves in the masonry blocks were aligned with ducts used to anchor the NSM reinforcement in the concrete footing. Seven wall specimens were tested, including walls reinforced with conventional and stainless steel bars, glass-fibre reinforced polymer (GFRP), and carbon-FRP (CFRP) reinforcement. The study demonstrated the feasibility and effectiveness of the NSM technique for new construction. Walls with NSM reinforcement showed a superior performance to those with EB reinforcement. It was shown that increasing the FRP reinforcement ratio may result in a change of failure mode, and as such, the increase in strength may not be proportional to the increase in reinforcement ratio. NSM steel-reinforced walls showed a superior performance in terms of strength, stiffness and the ductility associated with the formation of a plastic hinge at the base.

Degree

thesis:*
Department dc:contributor.department
Civil Engineering
Grantor
Queen's University at Kingston
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mierzejewski, Wojciech
Advisors dc:contributor.supervisor
  • MacDougall, Colin
  • Fam, Amir Z.

Subjects

dc:subject × 6

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/5695

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mierzejewski, Wojciech. Out-Of-Plane Bending Of Masonry Walls With Near-Surface-Mounted And Externally-Bonded Corrosion-Resistant Reinforcement. Queen's University at Kingston, 2010. https://hdl.handle.net/1974/5695