Back to search

Queen's University at Kingston

An Evaluation of the Environmental Protection Provided by Composite Liner Systems

Abstract

dc:description.abstract

The effect of calcium uptake by hydration and diffusion from an adjacent calcium-rich soil on the performance of a geosynthetic clay liner (GCL) is examined for three cases. In Case 1 the GCL rested directly on a soil with a high calcium (1800 mg/l) concentration in the pore water (called “calcium rich soil” herein). Case 2 involved a GCL resting on 300 mm of soil with a low (200 - 300 mg/l) calcium concentration in the pore water (“foundation soil”) overlying the calcium rich soil. In the third (“control case”), the GCL only rested on the foundation soil. The overburden pressure was 15 kPa. The moisture content of GCL increased to 96%, 86% and 108% in the first 279 days for Cases 1, 2 and 3 respectively. Under isothermal conditions, the GCL moisture content decreased to 80% and 67% for Cases 1 and 2 respectively and increased to 113% for Case 3. After 1100 days, the hydraulic conductivity (k) of the GCL was 4×10-11 m/s for Case 3 but had increased up to about 7×10-11 m/s and 2×10-10 m/s for cases with and without the foundation layer respectively. The results are used to calibrate finite element models. A good correlation was found between k the bulk void ratio (eB) of GCL. Leakage and contaminant transport through 10 mm diameter hole in a geomembrane in a composite liner involving a GCL is examined at a stress of 100 kPa for hydraulic heads of 0.3 or 1 m. When permeated with distilled water, the interface transmissivity (θ) was about 2.3 × 10 11 m2/s. After 800 days of permeation with 0.14M NaCl there was only about 3% increase in the flow despite an order of magnitude increase in GCL permeability near the hole because θ decreased from 2.3×10-11 m2/s to 1.1×10-11 m2/s and controlled the leakage despite the increase in GCL permeability. Numerical modeling demonstrated reasonable agreement with the observed transport.

Degree

thesis:*
Department dc:contributor.department
Civil Engineering
Grantor
Queen's University at Kingston
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Abdelatty, Khaled
Advisor dc:contributor.supervisor
  • Rowe, Kerry

Subjects

dc:subject × 6

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/6031

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Abdelatty, Khaled. An Evaluation of the Environmental Protection Provided by Composite Liner Systems. Queen's University at Kingston, 2010. https://hdl.handle.net/1974/6031