Back to search

Rice University

Data-Driven Modeling of Lung Deposition of Aerosol Medication Delivered by Metered Dose Inhalers

Abstract

dc:description.abstract

Chronic pulmonary diseases such as Asthma and COPD (Chronic Obstructive Pulmonary Disease) affect over 510 million worldwide. The most common form of treatment for the management of the diseases is a Metered Dose Inhaler (MDI). Numerous large-scale studies have demonstrated that 70-90% of patients misuse their MDIs leading to wasted medication and poor health outcomes. Due to the nature of inhaled therapy and delayed impact of MDI misuse on health outcomes, patients are unaware of their MDI use technique as well as the resulting lung deposition. In this thesis, I have developed and validated a predictive model of lung deposition corresponding to any MDI technique in three phases. Phase I: I conducted the first pilot study that quantitatively measured MDI technique from 23 physician-diagnosed asthma and COPD adult patients in an outpatient clinic setting. Our results showed that all patients made at least one technique error and 74% made at least three; our quantitative method of measurement recorded 60% more errors than the current gold standard method (using observation alone). Further, I derived an MDI technique model using a parameterized model with a trapezoidal approximation to inspiration curves and includes actuation timing and instantaneous flow-based parameterization. Phase II: To derive lung deposition for any MDI technique (ground truth estimation), I constructed and validated the first in vitro experimental testbed designed to emulate both inspiration and actuation mechanisms of any MDI use in a lab setting. Using this testbed, I determined the significance of inspiration and actuation parameters on in vitro lung deposition of aerosols delivered by Ventolin MDIs. Our results demonstrated that actuation parameters affected lung deposition more significantly (23% difference in lung deposition) than inspiratory flow parameters (<5%). Phase III: With a training dataset of MDI techniques and corresponding in vitro lung deposition, I determined that the model specification for a linear mixed effects model of lung deposition of aerosol from Ventolin MDIs was a function of quadratic inspiration and actuation parameters. I validated the model against in vitro lung deposition measured for the MDI techniques (non-trapezoidal) recorded from patients and had a testing RMSE of 2.3% lung deposition. Hence, we demonstrated the methodology and validation for developing a data-driven model of lung deposition of aerosol medication delivered by any MDI, based on patient representative inhaler use techniques.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering
Department thesis:degree_department
Electrical and Computer Engineering
Grantor
Rice University
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Biswas, Rajoshi
Advisor dc:contributor.advisor
  • Sabharwal, Ashutosh
Committee member dc:contributor.committeemember
  • Grande-Allen, Jane

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Citation
Biswas, Rajoshi. "Data-Driven Modeling of Lung Deposition of Aerosol Medication Delivered by Metered Dose Inhalers." (2018) Diss., Rice University. <a href="https://hdl.handle.net/1911/105804">https://hdl.handle.net/1911/105804</a>.

Chain of custody

source
Harvested from
Rice University
Base URL
repository.rice.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Biswas, Rajoshi. Data-Driven Modeling of Lung Deposition of Aerosol Medication Delivered by Metered Dose Inhalers. Doctoral thesis, Rice University, 2018. https://hdl.handle.net/1911/105804