Back to search

Rice University

Cone penetrometer technology for hazardous waste site investigations

Abstract

dc:description.abstract

The common approach to investigating the extent of contamination at a hazardous waste site is to drill monitoring wells to obtain geotechnical and chemical information. A new technology is now being utilized at various hazardous waste sites in order to facilitate the hydrogeologic data collection process. The use of cone penetration testing has proven to be a relatively quick and inexpensive method for initial site investigations compared to current techniques. Cone penetrometer testing can quickly determine the stratigraphy of an area, the soil properties, and (by taking samples) the extent of contamination. The data are obtained immediately, which allows in-field evaluation and "on the spot" decisions, resulting in enhanced placement of monitoring wells and in some instances a substantial reduction in the number of wells needed. Fewer monitoring wells means a large cost savings. Applications of cone penetrometer testing are presented and recommendations for further research are discussed.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Engineering
Department thesis:degree_department
Environmental Science
Grantor
Rice University
Year dc:date.issued
1989

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Smythe, Julie Miller
Advisor dc:contributor.advisor
  • Bedient, Philip B.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Callnumber
Thesis Env. Sci. 1989 Smythe
Dc Identifier Citation
Smythe, Julie Miller. "Cone penetrometer technology for hazardous waste site investigations." (1989) Master’s Thesis, Rice University. <a href="https://hdl.handle.net/1911/13397">https://hdl.handle.net/1911/13397</a>.

Chain of custody

source
Harvested from
Rice University
Base URL
repository.rice.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Smythe, Julie Miller. Cone penetrometer technology for hazardous waste site investigations. Masters thesis, Rice University, 1989. https://hdl.handle.net/1911/13397