Back to search

Rice University

Absolute calibration of a retarding-potential Mott polarimeter

Abstract

dc:description.abstract

Mott polarimeters are used in many areas of physics to determine the spin polarization of electrons in studies of processes dependent on the electron's intrinsic spin angular momentum and associated spin magnetic moment. Mott polarimeters work by measuring the left-right asymmetry in the spatial distribution of electrons scattered from high-Z nuclei. The polarization of the incident electrons is related to the measured asymmetry via a parameter known as the effective asymmetry (Sherman) function, S$\sb{\rm eff}$, which must be determined through calibration. This work describes a novel technique for calibrating a Mott polarimeter that makes use of electrons of accurately known polarization obtained through Penning ionization reactions involving electron spin polarized He(2$\sp3$S) metastable atoms. This technique has been used to calibrate a compact retarding-potential Mott polarimeter, and the values of S$\sb{\rm eff}$ are presented for both gold and thorium target foils under a variety of operating conditions.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Natural Sciences
Department thesis:degree_department
Space Science
Grantor
Rice University
Year dc:date.issued
1992

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Oro, David Michael
Advisor dc:contributor.advisor
  • Dunning, F. B.

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Callnumber
Thesis Sp. Sci. 1992 Oro
Dc Identifier Citation
Oro, David Michael. "Absolute calibration of a retarding-potential Mott polarimeter." (1992) Master’s Thesis, Rice University. <a href="https://hdl.handle.net/1911/13682">https://hdl.handle.net/1911/13682</a>.

Chain of custody

source
Harvested from
Rice University
Base URL
repository.rice.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Oro, David Michael. Absolute calibration of a retarding-potential Mott polarimeter. Masters thesis, Rice University, 1992. https://hdl.handle.net/1911/13682