Back to search

Rice University

A finite element approach towards biomechanical optimization of prophylactic vertebroplasty

Abstract

dc:description.abstract

Vertebroplasty has the potential to be a highly effective vertebral fracture prevention treatment, but the procedure must first be optimized for maximum benefit and minimal risk of safety to the patient. The procedure involves the percutaneous injection of a liquid bone cement into the vertebral body, which upon hardening provides instantaneous structural reinforcement. This research characterizes the effects of bone cement volume, material properties and distribution patterns on the global and internal vertebral biomechanics after prophylactic vertebroplasty in order to optimize these cement properties based on biomechanical efficacy and risk of complications which pose a threat to patient safety. In light of the many factors affecting the biomechanical outcome, a computational approach was employed since multiple analyses can be repeated on the same specimen. The accuracy of the models is assured by using realistic, image-based finite element models of human vertebral bodies that are specimen-specific, anatomically detailed and calibrated to experimental results. Prophylactic vertebroplasty was simulated on these models under various cement configurations and their biomechanical efficacies were evaluated based on the criteria for biomechanical success developed in this research---maximum mechanical reinforcement to reach low fracture risk levels with minimal amount of cement and maintenance of intravertebral mechanical compatibility to retain the normal dynamics of the weight-bearing spine. The biomechanically optimal bone cement is determined as one that results in a spatially dispersed distribution when injected into the vertebral body. The higher vertebral reinforcements achieved with a dispersed cement fill may lower the risk of complications due to cement leakages since smaller cement volume would be just as biomechanically effective. Furthermore, the disperse fill results in minimal intravertebral stress concentrations that may reduce the risk of subsequent fractures in the adjacent untreated vertebrae. Now that the bone cements with spatially dispersed fill patterns is known to produce optimum biomechanical effects, the biochemistry of materials with this unique characteristic can be specifically tailored to include biodegradability and drug release capabilities for various applications that require the merger of fracture prevention, tissue engineering and drug delivery innovations into one without any concerns for adverse biomechanical affects.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering
Department thesis:degree_department
Bioengineering
Grantor
Rice University
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sun, Kay
Advisor dc:contributor.advisor
  • Liebschner, Michael A. K.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Callnumber
THESIS BIOENG. 2006 SUN
Dc Identifier Citation
Sun, Kay. "A finite element approach towards biomechanical optimization of prophylactic vertebroplasty." (2006) Diss., Rice University. <a href="https://hdl.handle.net/1911/18981">https://hdl.handle.net/1911/18981</a>.

Chain of custody

source
Harvested from
Rice University
Base URL
repository.rice.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Sun, Kay. A finite element approach towards biomechanical optimization of prophylactic vertebroplasty. Doctoral thesis, Rice University, 2006. https://hdl.handle.net/1911/18981