Back to search

Rice University

Difference frequency generation: Spectrometers and spectroscopy

Abstract

dc:description.abstract

The theory of difference frequency generation has been further developed. Derived from basic principles, the equations developed here accurately predict the conversion of power to the idler wave. Critical phasematching can now be modeled with ellipticity in both beams and the effects of double refraction and non-normal incidence upon the crystal treated. It is no longer necessary to focus the beams into the center of the crystal nor is it necessary to have an equal confocal parameter in the two drive beams. A mid-infrared spectrometer based on titanium:sapphire pumped difference frequency generation in silver thiogallate (AgGaS$\sb2$) has been constructed in order to conduct high resolution spectroscopy on free radicals. Detector limited sensitivity has been demonstrated with an estimated source bandwidth of 0.00003 cm$\sp{-1}$. The process used to calibrate scans has been improved and calibration accuracy of 0.001 cm$\sp{-1}$ is now routine. With the silver thiogallate spectrometer, the infrared spectrum of the monodeuterated propargyl radical (CH$\sb2$CCD) has been acquired. Approximately 250 lines have been positively identified and assigned to the $\nu\sb1$ C-D stretch in the region between 2300 cm$\sp{-1}$ and 2400 cm$\sp{-1}$. The spectrum consists of a-type transitions ($\Delta$K$\sb{\rm a}$ = 0) with a fully resolved K subband structure, in contrast to the CH stretch of the normal radical. This resolved structure is due to a P$\sb{\rm a}$-type Coriolis interaction or a Fermi resonance in the molecule. These interactions may be responsible for the fact that we were unable to identify the odd K subbands, though positive identification of the K$\sb{\rm a}$ = 0, 2, 4, and 6 subbands was made and used to determine rotational constants for the radical. A spectrometer based on difference frequency generation in gallium selenide (GaSe) was constructed. Precise phasematching characteristics were determined as well as the potential power produced in the process. The instrument is continuously tunable in the 8.8-15.0 μm wavelength region.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Natural Sciences
Department thesis:degree_department
Chemistry
Grantor
Rice University
Year dc:date.issued
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Eckhoff, Wade Charles
Advisor dc:contributor.advisor
  • Curl, Robert F., Jr.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Callnumber
THESIS CHEM. 1997 ECKHOFF
Dc Identifier Citation
Eckhoff, Wade Charles. "Difference frequency generation: Spectrometers and spectroscopy." (1997) Diss., Rice University. <a href="https://hdl.handle.net/1911/19152">https://hdl.handle.net/1911/19152</a>.

Chain of custody

source
Harvested from
Rice University
Base URL
repository.rice.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Eckhoff, Wade Charles. Difference frequency generation: Spectrometers and spectroscopy. Doctoral thesis, Rice University, 1997. https://hdl.handle.net/1911/19152