Back to search

Rice University

Dynamic response of multi-degree of freedom structure with sliding isolation system and uplift

Abstract

dc:description.abstract

In this study the two dimensional dynamic response of a Multi Degree of Freedom (MDOF) sliding isolated structure permitted to uplift is studied. The MDOF superstructure is supported by two sets of sliding bearings situated at both the ends of the base mat. The foundation supporting the sliding bearings is assumed to be flexible and modeled using two sets of viscoelastic spring-dashpot systems attached below the sliding isolation bearings. The nonlinear stick-slip behavior of the friction based sliding isolation system is modeled using a hysteretic Bouc-Wen model. A nonlinear analytical model is formulated which takes into account the linear equations of motion of the superstructure and the base mat with stick-slip behavior of sliding isolators and in addition the following effects: uplift and loss of contact at the sliding bearings, and variation of coefficient of friction with velocity and bearing pressure. For comparison purposes fixed base structure with uplift is also modeled. The analytical model is solved using a two-step solution methodology and Pseudo-force method is employed for calculating the nonlinear forces acting on the structure at the interface of sliding isolation system in both the horizontal (stick-slip) direction as well as the vertical (uplift-contact direction). The analytical model developed is validated using experimental results of a 1:4 scaled model. Parametric study is performed with the analytical model (at full scale) by varying the periods of the superstructure, time period of the sliding isolation system, slenderness ratio of superstructure, vertical stiffness of foundation and pulse excitation parameters. The dynamical response of the MDOF structure with sliding isolation and uplift permitted is compared with sliding isolation with uplift prevented and fixed base structure with uplift respectively. The behavior of the MDOF system is studied for both near-source earthquake ground motion and their corresponding cycloidal approximations. The results of the study highlight the advantages of the combined mechanism of sliding isolation and vertical uplift for reduction of structural response of a MDOF system, as compared to the case without uplift and the case without sliding.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Engineering
Department thesis:degree_department
Chemical and Biomolecular Engineering
Grantor
Rice University
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Vemuru, Venkata Srivishnu Mohan
Advisor dc:contributor.advisor
  • Nagarajaiah, Satish

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Callnumber
THESIS C.E. 2010 VEMURU
Dc Identifier Citation
Vemuru, Venkata Srivishnu Mohan. "Dynamic response of multi-degree of freedom structure with sliding isolation system and uplift." (2010) Master’s Thesis, Rice University. <a href="https://hdl.handle.net/1911/62170">https://hdl.handle.net/1911/62170</a>.

Chain of custody

source
Harvested from
Rice University
Base URL
repository.rice.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Vemuru, Venkata Srivishnu Mohan. Dynamic response of multi-degree of freedom structure with sliding isolation system and uplift. Masters thesis, Rice University, 2010. https://hdl.handle.net/1911/62170