Novel Methods for Reducing Breast Dose During Computed Tomography Scans

Abstract

dc:description.abstract

Pediatric female and young adult female patients who undergo computed tomography (CT) scanning may be at higher risk for developing radiation-induced breast cancer later in life. Thus, the purpose of this thesis was to both accurately quantify dose and explore new strategies for CT breast dose reduction. In order to determine dose reduction, dose quantification was first assessed through the development and validation of an empirical model for describing attenuation in CT and second through evaluation of the precision of dosimetry-related measurements obtained using three different models of CT scanners. Breast dose-savings was evaluated using CT dose index phantoms, anthropomorphic phantoms, and Monte Carlo computer modeling. Modifications to current scanning procedures, such as proper patient centering and beginning data acquisition with the x-ray tube facing a patient's posterior, were shown to minimize breast dose. Novel techniques, including varying the x-ray tube voltage during scanning and incorporation of a dynamic x-ray beam filter over the breasts, were also found to successfully reduce breast dose.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering
Department thesis:degree_department
Bioengineering
Grantor
Rice University
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mathieu, Kelsey Boitnott
Advisor dc:contributor.advisor
  • Mikos, Antonios G.

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Callnumber
THESIS BIOENG. 2011 MATHIEU
Dc Identifier Citation
Mathieu, Kelsey Boitnott. "Novel Methods for Reducing Breast Dose During Computed Tomography Scans." (2011) Diss., Rice University. <a href="https://hdl.handle.net/1911/70341">https://hdl.handle.net/1911/70341</a>.
Dc Identifier Other
MathieuK

Chain of custody

source
Harvested from
Rice University
Base URL
repository.rice.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mathieu, Kelsey Boitnott. Novel Methods for Reducing Breast Dose During Computed Tomography Scans. Doctoral thesis, Rice University, 2011. https://hdl.handle.net/1911/70341