Back to search

Rice University

An Automated System for Cryo-Electron Microscopy Sample Preparation

Abstract

dc:description.abstract

Cryo-electron microscopy (CryoEM) is a procedure that has become popular for imaging radiation intolerant structures under electron microscopes. CryoEM involves maintaining the sample at cryogenic temperatures throughout the imaging process This has the effect of minimizing damage caused by the electron beam, and results in higher quality images than can be obtained through more traditional imaging methods. The preparation of samples for cryo-electron microscopy studies is currently a labor and time intensive process. Samples must be applied to an imaging substrate under tightly controlled environmental conditions, formed into a thin film, vitrified with liquid ethane, and placed into temporary storage under cryogenic conditions. The grid preparation process is very sensitive to procedural factors, thus the successful creation of viable samples depends on tightly controlling the conditions under which grids are prepared. Several devices which automate portions of the specimen preparation process are currently in use; however, these systems heavily rely on a human operator to function properly. This thesis describes a system that is capable of fully automating the sample preparation process. The resulting system minimizes the need for human input during specimen preparation, improves process control, and provides similar levels of environmental control. Testing shows that the resulting system is capable of preparing samples without human interaction.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Engineering
Department thesis:degree_department
Mechanical Engineering
Grantor
Rice University
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Thompson, Zachary J.
Advisor dc:contributor.advisor
  • O'Malley, Marcia K.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Callnumber
THESIS M.E. 2011 THOMPSON
Dc Identifier Citation
Thompson, Zachary J.. "An Automated System for Cryo-Electron Microscopy Sample Preparation." (2011) Master’s Thesis, Rice University. <a href="https://hdl.handle.net/1911/70475">https://hdl.handle.net/1911/70475</a>.
Dc Identifier Other
ThompsonZ

Chain of custody

source
Harvested from
Rice University
Base URL
repository.rice.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation