Back to search

Rice University

Hardware- versus Human-centric Assessment of Rehabilitation Robots

Abstract

dc:description.abstract

Individuals with disabilities arising from neurological injury require rehabilitation of the distal joints of the upper extremities to regain the ability to independently perform activities of daily living (ADL). Robotic rehabilitation has been shown to effectively conduct high intensity, long duration therapy and quantitatively assess the effects of therapy. This thesis presents methods and results for validating rehabilitation devices for training and assessment. Traditionally, methods for validating rehabilitation robots relied on robotic characterizations, which enables comparison of different designs' performance independent of a human user. An example of this method is presented here, in particular quantifying the torque output, range of motion, closed loop position performance, and high spatial resolution of two rehabilitation devices. However, these traditional validation methods do not assess the effect wearing the robot has on the user, and a new assessment method has been developed to address this shortcoming of traditional methods. A novel hand and wrist device was assessed through kinematic analysis of synergistic movements, as quantified by velocity- and position-dependent metrics. This experimental approach is promising for the characterization of multi-articular wearable robots as measurement tools in robotic rehabilitation. Together, the two methods presented can be used to validate rehabilitation robotic devices.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Engineering
Department thesis:degree_department
Mechanical Engineering
Grantor
Rice University
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rose, Chad Gregory
Advisor dc:contributor.advisor
  • O'Malley, Marcia K.
Committee members dc:contributor.committeemember
  • Ghorbel, Fathi H
  • Dick, Andrew J

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Citation
Rose, Chad Gregory. "Hardware- versus Human-centric Assessment of Rehabilitation Robots." (2015) Master’s Thesis, Rice University. <a href="https://hdl.handle.net/1911/87786">https://hdl.handle.net/1911/87786</a>.

Chain of custody

source
Harvested from
Rice University
Base URL
repository.rice.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Rose, Chad Gregory. Hardware- versus Human-centric Assessment of Rehabilitation Robots. Masters thesis, Rice University, 2015. https://hdl.handle.net/1911/87786