Abstract

dc:description.abstract

The study of the tear film of the eye is important for understanding the causes of dye eye syndrome, a disease causing damage to the ocular surface resulting in discomfort for many people. A popular mathematical model describing the evolution of the tear film thickness over time is a fourth-order nonlinear partial differential equation (PDE). This model has been formulated two different ways to facilitate numerical approximations. The first way is just one PDE including a fourth derivative along with the boundary and initial conditions that is solved for the tear film thickness. The second is a system of coupled second-order PDEs, with the analogous boundary and initial conditions, describing the tear film thickness and pressure. Typically, the second formulation is used when computing the solution as the first poses challenges. These challenges are generally attributed to approximating a scaled fourth derivative and specifying a third derivative for one of the boundary conditions. In this thesis, I explore the computational differences between the two formulations of the tear film model in one spatial dimension. Both formulations are approximated by implementing a method of lines approach where spatial derivatives are approximated with second-order centered finite differences, and then the system of differential equations are integrated forward in time using a backward Euler method. The stability of each numerical method is proven analytically with von Neumann analysis, and the usefulness of each formulation is characterized by studying the condition number of each discretization for different parameters and boundary conditions. In particular, I examine the implications of the relationship between the lid function and boundary conditions. Lastly, a comparison is made with results from the two-dimensional equivalent model on a realistic blinking eye-shaped domain.

Degree

thesis:*
Name thesis:degree_name
Applied and Computational Mathematics (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
School of Mathematical Sciences (COS)

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kiesel, Emily
Contributors dc:contributor
  • Kara L. Maki

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Repository record dc:identifier
https://repository.rit.edu/theses/9896

Chain of custody

source
Harvested from
Rochester Institute of Technology
Base URL
repository.rit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Kiesel, Emily. Tear Film Model Formulation: A 1-D Exploration. Thesis thesis, https://repository.rit.edu/theses/9896