Back to search

Rochester Institute of Technology

The effect of heating area and Wheatstone bridge materials on a thermally actuated MEMS viscosity sensor

Abstract

dc:description.abstract

Being able to accurately measure oil viscosity in real time is critical for multiple applications. It can ensure that the oil being used to protect and lubricate gears and other mechanical elements is good. To do this a thermally actuated micro electromechanical systems (MEMS) based sensor has been previously developed. The sensor is able to measure viscosity by having the fluid couple with the oscillating diaphragm and monitoring the frequency, amplitude and quality factor of the waveform. To improve the accuracy of the sensor, 5 different versions were created to study the effects of heating area and the sensing material used in the Wheatstone bridge. To also improve the repeatability of the sensors and reduce sensor to sensor variation the fabrication process was improved. This included the use of SOI wafers and better diaphragm alignment through the use of a contact aligner with an IR attachment to show alignment marks through the wafer. For the Wheatstone bridge polysilicon and P+ diffusion resistors were evaluated. For the heater material polysilicon and P+ diffusion were evaluated. For the heater area 3 separate designs were made with different size polysilicon heaters but with the same P+ Wheatstone stone to allow just the heater size to be evaluated. To remove the effects of temperature on the sensors each sensor was run through a temperature sweep in air. The data was used to create a correction factor that applied to the fast Fourier transform (FFT) frequency to produce more accurate results for measurements taken above room temperature. To determine how sensitive each type was to changes in viscosity each type was placed in N100, N35 and N10 oils while their temperature went from 25°C to 80°C. These oils were used because they made specific ASTM standards to ensure they have a set viscosity for a given temperature. From testing it was determined that higher initial deflection of the diaphragm does not equate to a higher sensitivity.

Degree

thesis:*
Name thesis:degree_name
Electrical Engineering (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Department of Electrical and Microelectronic Engineering (KGCOE)

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Levine, Connor Michael
Contributors dc:contributor
  • Ivan Puchades

Subjects

dc:subject × 4

Identifiers

dc:identifier.*
Repository record dc:identifier
https://repository.rit.edu/theses/11569

Chain of custody

source
Harvested from
Rochester Institute of Technology
Base URL
repository.rit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Levine, Connor Michael. The effect of heating area and Wheatstone bridge materials on a thermally actuated MEMS viscosity sensor. Thesis thesis, https://repository.rit.edu/theses/11569