Rochester Institute of Technology
Characterizing TCAP Set-ups for Effective Separation on Hydrogen Isotope Species
Abstract
dc:description.abstractHydrogen isotope separation was investigated using a series of thermal cycling absorption process (TCAP) experiments. Pulse tests were conducted using deuterium injected into a protium flow over a range of superficial velocities, temperatures, particle sizes, and column diameters to quantify the efficiency of this process for a palladium on kieselguhr catalyst. The resulting response curves, obtained from residual gas analysis, were used to calculate the height equivalent to a theoretical plate (HETP) in each case. These values were then fit with van Deemter curves to illustrate the change in HETP over gas velocity. A strong positive correlation with temperature was found, as well as a positive correlation with particle size and a weak negative correlation with column diameter.
Degree
thesis:*- Name thesis:degree_name
- Physics (MS)
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Physics and Astronomy, School of
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hanby, James R
- Contributors dc:contributor
-
- Michael Pierce
Subjects
dc:subject × 5Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.rit.edu/theses/12320