Back to search

Rochester Institute of Technology

A Dynamic magnetic resonance imaging (MRI) phantom based on electric field induced residual dipolar couplings

Abstract

dc:description.abstract

Multi-center functional MRI (fMRI) research studies are advantageous but unavoidably introduce variations in the results due to differences in imager vendor, magnetic field strength, imaging pulse sequences, and many other aspects. These variations make combining data from different MRI centers risky. Even for a single MRI center, temporal variations over the course of a study can make combining data problematic. Therefore, it is necessary in both situations to perform quality assurance (QA) measurements on a regular basis. Unfortunately, there are no dynamic standards or phantoms as they are called in the MRI community, which can mimic the small, rapidly changing fMRI signal at a relatively large field-of-view (FOV) and number of magnetic field strengths. The goal of this research was to develop a dynamic phantom which mimiced the signal change in fMRI and hence could be used for QA procedures related to fMRI. A phantom was developed with a rapidly switchable MRI signal. This phantom consisted of a geometric grid, eight vials with solutions of known proton spin-spin relaxation time (T2) values, and a cylindrical electrical cell filled with a polar liquid, all surrounded by water. An electrical circuit was built to interface the phantom to an imager through the pulse sensor and produce pulsed electric (E) fields during the imaging sequence. The results of spin-echo, echo planar imaging (SE-EPI) imaging sequence showed that the signal changed by approximately 8% with the application of a 11.8 kV/m electric field. This change was found to be based on the residual dipolar couplings induced by the applied E field, directly related to the size of the field, and switchable in 50 μs.

Degree

thesis:*
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Chester F. Carlson Center for Imaging Science (COS)

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Qiu, Yujie
Contributors dc:contributor
  • Hornak, Joseph

Identifiers

dc:identifier.*
Repository record dc:identifier
https://repository.rit.edu/theses/2887

Chain of custody

source
Harvested from
Rochester Institute of Technology
Base URL
repository.rit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Qiu, Yujie. A Dynamic magnetic resonance imaging (MRI) phantom based on electric field induced residual dipolar couplings. Dissertation thesis, https://repository.rit.edu/theses/2887