Back to search

Rochester Institute of Technology

Shear Inducing Device for the Testing of Cell Fragility

Abstract

dc:description.abstract

Most blood pumps are designed to boost the pumping abilities of the heart by mechanical energy transfer using a rotor. Due to the nature of blood contacting devices, the various components of blood are subjected to shear stresses caused by the device. The accurate analysis and prediction of blood damage during the design phase of a device has been difficult to achieve. This has been complicated by both the inaccuracy of computer tools used to model the blood flow and the large uncertainty in the reported values of stress that damage blood components. Different components of blood, such as red blood cells, platelets and VWF (Von Willebrand Factor), have different sensitivities to shear stress. Further, the damage to blood components has been correlated to both the magnitude of the shear stress and duration of time that the components are exposed to that stress (exposure time). A device that is based on cylindrical Couette flow was developed by Rochester Institute of Technology called the Maglev (Magnetic Levitation) shearing device. This device has a magnetically suspended rotor thus reducing a major amount of friction when compared to pumps with bearings. The device is intended to have a single region of laminar Couette flow (between an inner rotating cylinder and a stationary housing) that exposes the fluid to stress. From prior work, the device was partially manufactured but never made to work. The two primary goals of this thesis are to fabricate a functional magnetically levitated shearing device to induce stress in blood and other fluids using the new fluid path design and to determine the damage done to bovine blood at different exposure and stress levels.

Degree

thesis:*
Name thesis:degree_name
Mechanical Engineering (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Mechanical Engineering (KGCOE)

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Raghunathan, Ramnath
Contributors dc:contributor
  • Steven W. Day

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Repository record dc:identifier
https://repository.rit.edu/theses/8567

Chain of custody

source
Harvested from
Rochester Institute of Technology
Base URL
repository.rit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Raghunathan, Ramnath. Shear Inducing Device for the Testing of Cell Fragility. Thesis thesis, https://repository.rit.edu/theses/8567