Abstract
dc:description.abstractThere has been relatively little research into the assessment of socket fit in upper-limbprosthetics, in comparison to lower-limb prosthetics. Whilst this reflects the smallerpopulation of potential users, the global need for devices is nonetheless substantial. Themeasurement of socket fit was explored through a literature review and suitablequantifiable parameters identified, with a focus on the relative movement between socketand residuum, governed by their mechanical coupling. To clarify the use of these variablesin socket evaluation, a good ‘fit’ was defined as the optimal balance between the couplingof the socket, and a measure of tissue health. A novel system was then developed for thequantification of coupling, based around the use of a 3D scanner. This used sphericaltargets to define Templates for different objects in a scan, and was shown to be capable ofidentifying and measuring the relative pose of those objects, specifically a socket relativeto an arm. This approach was used to demonstrate the measurement of coupling with ananatomically intact subject. Evaluation of the apparatus required a test socket, and ananalysis of user needs was performed, resulting in the choice of an open-frame design. Anovel tool was then created to aid the design of those components (pads) interfacingdirectly with the residuum. It was demonstrated that the tool can be used to apply a knownpressure distribution to a relatively large area of tissue, before capturing the shape of theresultant tissue displacement. The specific importance of socket coupling for users of myo-electric upper-limb prostheses was also addressed, as artefactual signals can be generatedwhen socket perturbations cause electrodes to lift or slip relative to the residuum. Furthernovel measurement techniques were introduced to quantify this movement envelope, withthe results informing the development of a new electrode housing through several cyclesof prototyping. This device, which mechanically partially de-couples the electrode from thesocket within an appropriate working volume, was used to demonstrate reductions insignal artefacts in comparison with a standard electrode housing.
Degree
thesis:*- Name dc:type.qualificationname
- Doctor of Philosophy (PhD)
- Level dc:type.qualificationlevel
- Doctoral (Level 8)
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Prince, Michael
Rights
- Licence dc:rights.license
- Language dc:language
- en
Identifiers
dc:identifier.*- Identifier
- oai:salford-repository.worktribe.com:2680342