U. of Salford
Development of a design specification for a context-appropriate passive adjustable wrist prosthesis: A Uganda-based study.
Abstract
dc:description.abstractMost research into upper limb prosthetics has focused on the design and control of hands. However, research has suggested that addition of a functional wrist to a simple hand may yield better results for persons with upper limb absence (PWULA) than a highly dexterous hand without a wrist. Attempting tasks in the absence of an adjustable wrist leads to compensatory movements in proximal joints and a reduced overall functionality. While a small number of studies have investigated passive prosthetic wrists and some devices are available commercially, their design rationale is rarely reported, and no consensus exists on which type of device performs best. Furthermore, except for a growing number of manufacturers in China, most devices on the market are designed in Europe or the USA for high income contexts. There are, therefore, very few studies of the needs of PWULA in low- and middle-income countries (LMIC), and to the author’s knowledge, none that directly informs wrist prosthesis design in such settings.This PhD aimed to develop a design specification for a passive prosthetic wrist suitable for PWULA in LMIC. The first study, a secondary analysis of interviews with participants in Uganda and Jordan identified priority activities of daily living (ADLs): hand washing clothes, sweeping, peeling, driving, lifting objects and reading and writing, these studies strongly informed consecutive studies and highlighted the underrepresentation of LMIC user needs. The second study evaluated the reliability of different setup procedures to wrist and forearm kinematics measurement equipment (electro-goniometers and torsiometers), setup procedure 2 provided the highest reliability. This provided a protocol for using electro-goniometers and torsiometers to measure wrist and forearm kinematics in LMIC that have no access to equipped gait laboratories. The third study used the validated setup procedure in study 2 to capture wrist and forearm kinematics while performing a select ADLs identified in study 1. The results reported functional range(s) of motion (FROM) of: Fl/Ex: ~85°, Rd/Ud: ~50° and ~Pr/Su: 50°. Using the virtual neutral concept, we identified task specific optimal and worst orientations that were validated using a movement quality scale. The findings further showed that tasks were performed with the wrist biased towards Ex, Rd and Pr.Together, these studies provide three main contributions: (1) the identification of LMIC relevant ADLs to inform UL kinematics studies (ii) a reliable wrist and forearm kinematics measurement protocol (iii) a virtual neutral concept that can be used to determine optimal wrist and forearm orientations, (iv) functional ranges of motion and a normative database of wrist and forearm kinematics. These findings establish the first evidence-based design framework and recommendations for passive prosthetic wrists tailored to the needs of PWULA.
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mulerwa, Martha
- Author Identifier dc:creator.authoridentifier
Rights
- Licence dc:rights.license
- Language dc:language
- en
Identifiers
dc:identifier.*- Identifier
- oai:salford-repository.worktribe.com:4512989