Back to search

University of Saskatchewan

Residual Set-up Error for Canine Brain Radiation Therapy

Abstract

dc:description.abstract

When targeting a structure in three-dimensional space, the repositioning accuracy of the patient on the treatment table should be consistent among all radiation treatment sessions. Immobilization devices are used reposition the patients, and imaging systems built into the radiation machine are used to correct the patient’s position prior to treatment. Radiation oncologists usually treat a margin of normal tissue around the tumor called planning target volume (PTV) to account for interfraction (set-up errors) and intrafraction motion (such as motion due to respiration). The size of the PTV margin is an estimate of the targeting accuracy that can be achieved using immobilization devices and image guidance. The PTV margin reported for stereotactic radiation therapy (SRT) and stereotactic radiosurgery (SRS) to treat canine brain tumors ranges from 0-3 millimeters (Kelsey, Gieger, and Nolan 2018; Griffin et al. 2014; Dolera et al. 2017). An ideal margin would be a narrow margin to minimize the chance of toxicity to the normal brain and wide enough to cover the entire tumor target. The size of the PTV margin also depends on the radiation therapy delivery technique and the fractionation scheme (dose of radiation for each treatment session) planned for determined tumor types and locations. Accurate patient set-up and adequate PTV margin selection are required to minimize the chance of radiation side effects to the normal tissue surrounding the tumor region and to maximize tumor control. This is particularly relevant for SRS and SRT treatments, as higher doses of radiation are used to treat cancers compared to conventional radiation protocols.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Small Animal Clinical Sciences
Department thesis:degree_department
Small Animal Clinical Sciences
Grantor
University of Saskatchewan
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Morimoto, Celina Yukari 1992-
Advisor dc:contributor.advisor
  • Mayer, Monique
Committee members dc:contributor.committeemember
  • Waldner, Cheryl
  • Sidhu, Narinder
  • Kundapur, Vijayananda
  • Mauldin, Neal
  • Lanovaz, Joel
  • Sandmeyer, Lynne
ORCID person:identifier.orcid

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/11900

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Morimoto, Celina Yukari 1992-. Residual Set-up Error for Canine Brain Radiation Therapy. Masters thesis, University of Saskatchewan, 2019. https://hdl.handle.net/10388/11900