Back to search

University of Saskatchewan

The Behaviour of End Plate Connections

Abstract

dc:description.abstract

SYNOPSIS This thesis is a presentation of the research done on an end-plate connection consisting of a 1/2 inch plate welded to the end of a 10WF21 beam and then bolted with four high strength bolts to the flange of an 8WF28 column. The use of electrical resistance strain gages to find bolt loads proved very satisfactory. The use of a 1/2 inch end plate proved to be sufficient for the connection. The amount of bolt pretension greatly affected the overall behaviour of the connection. The introduction of stiffeners to the column strengthened the connection.

Degree

thesis:*
Name thesis:degree_name
Bachelor of Science in Engineering (B.E.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Civil Engineering
Department thesis:degree_department
Civil Engineering
Grantor
University of Saskatchewan
Year dc:date.issued
1966

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hellquist, Terrance I.
Advisor dc:contributor.advisor
  • Wright, P.M.
Committee member dc:contributor.committeemember
  • McMillan, Larry K.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/13933

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Hellquist, Terrance I.. The Behaviour of End Plate Connections. Masters thesis, University of Saskatchewan, 1966. https://hdl.handle.net/10388/13933