Back to search

University of Saskatchewan

Segmentation in the Canine Head

Abstract

dc:description.abstract

This thesis is comprised of two research projects. Both projects focus on the contouring phase of the computerized treatment planning process for radiation therapy. Lack of agreement between human radiation oncologists on the exact location of normal tissues and tumor is well-established; this graduate work explored the lack of agreement between veterinary radiation oncologists, the impact of lack of agreement on delivered dose, and whether agreement could be improved using a new contouring method. The goal of the first study was to quantify the dosimetric impact of the lack of interobserver agreement on GTV delineation for canine meningioma. A previously reported population of 13 dogs with GTVs contoured on CT alone and on registered CT-MR by 18 radiation oncologists was used. The ‘true’ GTV was generated for each dog using a STAPLE algorithm, and ‘true’ brain, defined as whole brain minus true GTV. Treatment plans were generated for each dog-observer combination, using criteria applied to the observer’s GTV and brain contours. The mean percent coverage of true GTV by prescribed dose was higher for CT-MR plans than for CT plans (mean difference 5.9%, 95% CI 3.7 to 8.0, p <0.001). There was no difference in mean volume of true brain receiving ≥ 24 Gy and in maximum true brain dose between CT plans and CT-MR plans (p ≥ 0.198). CT-MR plans were more likely to pass criteria for true GTV and brain than CT plans (OR 1.75, 95% CI 1.02 to 3.01, p = 0.044). A significant dosimetric impact was demonstrated when GTV contouring was performed on CT alone compared to CT-MR. The second study researched a new method for contouring the OP with only CT imaging. Expert consensus OP contours were delineated on registered CT and MRI for eight dogs. Twenty-one ROs contoured the OP on CT using their preferred method, and again after being provided with an training material demonstrating contouring on the optic plane. The DSC was used to assess contour accuracy. The median DSC before training was 0.31 (5th and 95th percentile, 0.06, 0.48) and the median DSC after training was 0.41 (0.18, 0.53). The mean DSC was higher after training than before training (mean difference = 0.10, 95% CI 0.08 to 0.12, p <0.001) on average across all observers and patients. Use of MRI for OP contouring is expected to provide the highest accuracy, but if CT is used, the use of an optic plane should improve accuracy.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Small Animal Clinical Sciences
Department thesis:degree_department
Small Animal Clinical Sciences
Grantor
University of Saskatchewan
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Walther, Eric
Advisor dc:contributor.advisor
  • Mayer, Monique
Committee members dc:contributor.committeemember
  • MacDonald-Dickinson, Valorie
  • Boshoven, Eric
  • Mauldin, Neal
  • Sidhu, Narinder
  • Deveau, Michael

Subjects

dc:subject × 2

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/14221

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Walther, Eric. Segmentation in the Canine Head. Masters thesis, University of Saskatchewan, 2022. https://hdl.handle.net/10388/14221