University of Saskatchewan
A Double-Roof Chinese Solar Greenhouse Environment Monitoring and Simulation
Abstract
dc:description.abstractThere has been no research on thermal performance of double-roof Chinese solar greenhouse (DRCSG) yet. In this study, A data acquisition system was installed to monitor the microclimate of the DRCSG in Alberta for one year from March 8, 2022, to February 28, 2023. A favorable thermal performance was exhibited with the indoor air temperature maintained above 12℃ for 88.1% of the year and 93.7% of the time without supplemental heating from March to October 2022. The indoor temperature was 10℃ when the ambient temperature was -36.9℃ on December 20, 2022. To simulate the thermal environment of the DRCSG, a computer model SOGREEN was used to assess its accuracy. The simulation was conducted by inputting preconditions including ambient climate conditions and material thermal properties. The results showed the simulated and measured microclimate parameters had large differences because SOGREEN is designed for typical Chinese solar greenhouses with a single south roof. Hence, a new model was developed by the computational fluid dynamics (CFD) software ANSYS Fluent to simulate the thermal environment of the DRCSG. Two typical days in different seasons were selected for simulation. The CFD model demonstrated a good performance in simulating the thermal environment. The relative differences between the measured and simulated air temperatures were 5%, 4%, and 1% in March, April, and July, respectively, with absolute deviations of 0.7℃, 0.7℃, and 0.3℃. As observed in the one-year monitoring period, the DRCSG faced a notable challenge in high humidity with 50.4% of the time of relative humidity (RH) exceeding 80%. To address this issue, a mechanical ventilation dehumidification system was used. This system involved an exhaust fan, an air inlet, a recirculation fan, and a humidistat controller. The results showed that this dehumidification system was effective. The frequency of RH exceeding 80% decreased from 50.7% during March 29-31 without mechanical ventilation to 0.2% during May 2-4 with the operation of the system with the temperature protection and RH off-on setpoints set at 13℃ and 75-78%, respectively. In summary, this DRCSG has shown to be energy-efficient for the Canadian cold region. The SOGREEN model had large discrepancies for simulating the DRCSG’s thermal environment. This study developed a CFD model that perform well in simulating the DRCSG’s thermal conditions. Furthermore, the mechanical ventilation dehumidification system was demonstrated effective in controlling the high humidity conditions in the greenhouse.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (M.Sc.)
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department thesis:degree_department
- Mechanical Engineering
- Grantor
- University of Saskatchewan
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zhang, Yongsheng
- Committee members dc:contributor.committeemember
-
- Guo, Huiqing
- Zhang, Chris
- Tanino, Karen
- Huang, Shaobo
Subjects
dc:subject × 3Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10388/15378