Back to search

University of Saskatchewan

THE DESIGN OF AN ECG MORPHOLOGY PROCESSOR CHIP

Abstract

dc:description.abstract

This thesis presents the design of an integrated circuit (IC) whose function is to calculate the measure of fit between the morphology (shape) of a newly recorded ECG waveform to that of previously recorded reference waveforms. This morphological information is an important factor in the detection and diagnosis of certain heart arrhythmias. The morphology processor chip is to be one module of a unique interac-tive ECG arrhythmia analysis system which uses Hilbert Transform processing of the ECG signal. In order to achieve the processing speeds necessary to perform real-time analysis of multiple ECG leads, the pattern recognition algorithm was implemented on an integrated circuit. In this report the design, simulation, and layout of the ECG morphology proces-sor chip is presented. The interrelationship and trade-offs involved in the selection of design parameters, such as system interfacing, data word size, algorithm precision, and circuit layout size, are discussed and analyzed during the development of the morphol-ogy processor chip. The circuit of the morphology processor is shown to consist of seven main com-ponents; a square-root extractor, a multiplier, an adder, a RAM memory unit, a matrix update unit, an address unit, and a finite state machine control unit. Circuit descriptions and schematics of each of these units are included. The layout and pin assignment of the entire 34 pin chip is presented along with SILOS simulation results for the com-plete circuit. A detailed method for testing the fabricated morphology processor chip is also included. As well, the simulation and testing of a fabricated memory chip, consist-ing of the morphology processor's memory unit, is detailed. Test results from this memory chip verify the memory circuit's functionality.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Masters
Department thesis:degree_department
Biomedical Engineering
Grantor
University of Saskatchewan
Year dc:date.issued
1990

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cram, Robert Donald
Advisor dc:contributor.advisor
  • Bolton, R. J.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/15604

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Cram, Robert Donald. THE DESIGN OF AN ECG MORPHOLOGY PROCESSOR CHIP. Masters thesis, University of Saskatchewan, 1990. https://hdl.handle.net/10388/15604