Back to search

University of Saskatchewan

Synergizing Engineering and Veterinary Science Techniques for Advanced Device Design, Testing, and Assessment in Canine Rehabilitation Therapy

Abstract

dc:description.abstract

Continuous Passive Motion (CPM) devices have been used to assist physicians conducting human rehabilitation; however, similar machines specific for canine rehabilitation have not been found in the reviewed literature. The lack of this technological tool could directly affect rehabilitation outcomes because it was found that these devices' design to comply full Range of Motion (ROM) could positively affect the recovery of human patients. Consequently, variability produced by the manual implementation of CPM exercises can be reduced by the use of a machine of great precision, improving the effects of the therapy and leading to a faster recovery with better rehabilitation results. This thesis targets the design and preliminary testing of a device to automate and enhance the implementation of passive motion exercises in canines’ stifle joints in terms of accuracy in angular positioning. Even more, the proposed solution will replicate the manual clinical procedure by sensing the force generated by the limb as opposed to the device motion, to avoid any further damage to the joint, while also achieving ROM as much as allowed by the affected joint and by the patient. It has also been considered the relevance of determining the specific conditions where the proposed device could be used. Therefore, this approach began with a literature review and an analysis of the common injuries in the human knee joint. Then, passive motion implementation in some animals is reviewed, focusing mainly on the stifle joint. Finally, this knowledge base is interpolated into canines to determine stifle’s parts of interest and medical conditions. Followed by this review, a physical analysis of the canine stifle is carried out to determine torque requirements and biomechanical components properties. This analysis provided the necessary parameters to build the mechanical and electrical system, so that accurate functional performance is achieved. Similarly, the design of a device that could fit different dog sizes or breeds was properly analyzed and the corresponding considerations were provided. Three prototype versions are presented and explained, which contribute towards the design of a commercial device. Finally, the electromyographic (EMG) signal of the canines was considered as a resource to improve the device’s operation. It was considered as a feedback signal to determine the condition of the muscles while the therapy is in process. A review of EMG signals in canine limbs is included, as well as the use of deep neural models to process these signals in an specific application. Also, the use of EMG signals in this project is discussed, with the limitations for clinical tests.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Department thesis:degree_department
Biomedical Engineering
Grantor
University of Saskatchewan
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Erazo Sosa, Andres Sebastian
Advisor dc:contributor.advisor
  • Ko, SeokBum
Committee members dc:contributor.committeemember
  • Chen, Li
  • Sparrey, Carolyn
  • Zhang, Chris
  • Wu, FangXiang
  • Mehr, Aryan Saadat
  • Pinto, Romany
ORCID person:identifier.orcid

Subjects

dc:subject × 3

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/15816

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Erazo Sosa, Andres Sebastian. Synergizing Engineering and Veterinary Science Techniques for Advanced Device Design, Testing, and Assessment in Canine Rehabilitation Therapy. Doctoral thesis, University of Saskatchewan, 2024. https://hdl.handle.net/10388/15816