INVESTIGATING THE IMPACT OF FREEZE-THAW CYCLES ON THE INTERNAL STRUCTURE OF ASPHALT CONCRETE USING IMAGING TECHNIQUES
Abstract
dc:description.abstractAsphalt concrete (AC) is a widely used material by transportation agencies in pavement construction. AC is a viscoelastic material that is susceptible to deterioration due to environmental changes, particularly freeze-thaw (F-T) cycles. Climate change can increase the number of F-T cycles, which can accelerate the damage in AC pavements. Therefore, it is necessary to optimize the mix design and materials selection of AC pavements to maximize their F-T durability and preserve natural resources. This study investigates the impact of F-T cycling on AC mixtures with different compositions using X-ray computed tomography (CT) scanning and digital camera imaging (DCI). Samples were prepared from five AC mixtures, which were collected from actual construction projects in Saskatchewan, Canada. The mixtures had various types of binder (virgin and modified), and different contents of reclaimed asphalt pavement (RAP). X-ray CT scanning was used to evaluate the microstructural changes of the AC samples based on changes in the structure of air voids and cracking in coarse aggregates. DCI was used to characterize the cracks in coarse aggregates, within the same AC mixtures, to evaluate the capacity of DCI to be an accessible, user-friendly, and cost-effective alternative to X-ray CT scanning. Indirect tension (IDT) test was completed for the AC mixtures before conditioning to measure their initial tensile strength. The microstructure of the AC samples was analyzed at 0, 30, 60, and 90 F-T cycles. Each cycle has 12 hours of freezing at -20˚C followed by 12 hours of thawing at +20˚C. The volume of samples was also measured at each stage of F-T conditioning. Correlation analysis and analysis of variance (ANOVA) were conducted to study the effects of changing AC compositions on their microstructure evolution with F-T cycling. Results from X-ray CT scanning showed that the structure of air voids and cracking in coarse aggregates varied amongst the tested mixtures. The use of a polymer-modified binder in AC reduced the impact of F-T cycling on air voids and cracking in coarse aggregates. The mixture containing a polymer-modified binder showed the lowest increase in air voids and cracking in coarse aggregates after 90 F-T cycles amongst the tested mixtures. These results agree with the observations from the volume measurements of the AC samples. ANOVA results showed that the fine aggregate portion in AC mixtures had a statistically significant impact on the number of air voids, their area, and the average size of air voids. These results suggest that aggregate gradation needs to be considered when assessing the F-T durability of AC mixtures. Additionally, ANOVA results showed that the number of F-T cycles has a statistically significant impact on the change in total area of air voids within the AC mixtures. A statistically significant correlation was observed between the number of F-T cycles and the area and width of cracks in coarse aggregates. F-T cycling induces thermal stresses that can weaken the binder-aggregate bond, facilitating crack initiation and propagation. Changes in binder characteristics under F-T cycles may also affect its adhesion to the surface of aggregate particles. Moisture ingress during F-T cycling can increase the size of cracks in coarse aggregates. Initial IDT values, before F-T conditioning, showed a statistically significant correlation with the binder type that was used in the mixtures (virgin binder vs. modified binder). Additionally, the initial IDT values of the test mixtures showed a statistically significant correlation with the changes in the internal structure of the tested mixtures, in terms of average size of air voids, total area of cracks in coarse aggregates, and average length of cracks in coarse aggregates. There was a good agreement between DCI and X-ray CT scanning in identifying that the mixture containing a polymer-modified binder has the lowest values amongst the tested mixtures for total number, total area, and average length of cracks in coarse aggregates after 90 F-T cycles. The trends for the changes in the cracking parameters amongst the tested AC mixtures were comparable between the DCI and X-ray CT scanning. There were some differences in parameters like the average crack width, which can be attributed to the lower resolution of DCI when compared to the resolution of X-ray CT scanning. Results from X-ray CT scanning showed that polymer-modified binders can be used in AC mixtures containing RAP to offset the negative impact of RAP on their F-T durability. Further research and testing are needed to identify the optimum RAP content in AC mixtures containing polymer-modified binders without compromising the F-T durability of the mixture. Further research and testing are required with additional mixtures to evaluate more binder types, additional RAP contents, and different aggregate blends. The database from this testing data can be used to develop performance-based guidelines and specifications for materials selection and design of AC mixtures in F-T conditions. This research showed promising results for using DCI, as a readily available and cost-effective alternative for X-ray CT scanning, to detect the microstructural changes in AC mixture due to F-T cycling. Further testing and research are needed to refine the proposed methodology in this study, which can make DCI ready to be adopted by practitioners to assess the F-T durability of AC.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (Ph.D.)
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Civil Engineering
- Department thesis:degree_department
- Civil and Geological Engineering
- Grantor
- University of Saskatchewan
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Alawneh, Mai
- Advisor dc:contributor.advisor
-
- Soliman , Haithem
- Committee members dc:contributor.committeemember
-
- Peng, Jian
- Boulfiza, Moh
- Odeshi, Akindele
- Baaj, Hassan
- ORCID person:identifier.orcid
Subjects
dc:subject × 1Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10388/15885