Back to search

University of Saskatchewan

ASYNCHRONOUS OPERATION OF SYNCHRONOUS GENERATORS

Abstract

dc:description.abstract

If a synchronous generator is allowed to operate asynchronously following a loss of synchronism, it is possible to avoid the complete loss of its capacity. The purpose of this thesis is to critically examine the performance of hydro- and turbo- generators under this abnormal mode of operation. An analytical technique is developed, based on the assumption of operation at a constant slip. The validity of the analysis is tested by using the results of experimental investigations. The analysis is applied for studying the effects of different modes of the field winding connection on the constant as well as pulsating components of the various quantities. The permissible asynchronous power output is evaluated on the basis of the constraints set by the stator and rotor losses, the reactive power demand, the terminal voltage drop, the induced field voltage and pulsations in these quantities. In fact, the slip will be of a pulsating nature because of rotor asymmetries. By means of digital simulation studies, the effects of different modes of the field winding connection on the amplitudes as well as waveshapes of the slip pulsations, while delivering different values of asynchronous power, are investigated. The nature of the various electrical quantities in the presence of slip pulsations is also studied. The results of these studies are compared with the performance characteristics obtained from the constant-slip analysis and the validity of the assumption of a constant slip is discussed. By a logical extension of the constant-slip analysis, the presence of slip pulsations is taken into consideration in terms of a series of harmonic components in the various quantities. A harmonic balance technique is developed for calculating these harmonic components. The results obtained are in good correlation with' those of the digital simulation studies based on the non-linear differential equations of the machine. In the case of turbo-generators, the asynchronous performance will be affected by the eddy currents induced in the solid parts of the rotor. A theoretical analysis is developed in which these currents are represented by a single current sheet in the pole region and three different current sheets in the slotted region. On this basis, an equivalent generator model is obtained in terms of different parameters in the d- and q- axes.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Department thesis:degree_department
Electrical Engineering
Grantor
University of Saskatchewan
Year dc:date.issued
1975

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Seetharaman, Chandrasekharapuram Krishnaiyer
Advisors dc:contributor.advisor
  • El-Serafi, A.M.
  • Verma, S. P.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/15904

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Seetharaman, Chandrasekharapuram Krishnaiyer. ASYNCHRONOUS OPERATION OF SYNCHRONOUS GENERATORS. Doctoral thesis, University of Saskatchewan, 1975. https://hdl.handle.net/10388/15904