Back to search

University of Saskatchewan

PUBLIC AND ASSET SAFETY INVOLVING TRANSMISSION LINE STRUCTURES

Abstract

dc:description.abstract

The grounding system of transmission lines serves a few key purposes in the operation of transmission lines, including lightning protection, ensuring the operation of protection devices, and personnel safety. For transmission lines using lattice or tubular steel structures, the foundations of transmission line structures are utilized as the preferred grounding electrodes due to their depth and large size. Due to the continuing load growth and limited available land in urban areas, there is a need for the public to push utilities to allow specific development within existing transmission line corridors, such as parking lots, parks, trails, etc. Those developments increase the liability to utility companies and risk to the public if there is a ground-related fault at the nearby transmission line structure. Meanwhile, the regulatory bodies prefer to keep all the infrastructure within the same corridor, including transmission lines, pipelines, and railways. The co-location of different infrastructures raises an interference issue, which can negatively impact each party. This research investigates the safety of the public and assets involving transmission line grounding systems. It addresses two critical aspects: public safety within transmission line corridors during ground-related faults and the corrosion of transmission line tower foundations due to stray currents from adjacent infrastructures, including pipelines and electrified railways. The first part of the research focuses on developing a probabilistic risk assessment (PRA) method to evaluate the risk posed to the public near transmission line structures under fault conditions. This is crucial as more transmission lines are being constructed near urban areas due to increased load growth, raising safety concerns regarding touch and step voltage hazards. The PRA method quantifies the risk by considering factors, such as the fault probability, human presence, and the physiological effects of electrical currents, particularly ventricular fibrillation. The research utilizes historical data from Manitoba Hydro to determine the probability of different fault types and clearing times, enhancing the accuracy of the risk assessment. Additionally, the field monitoring data from Winnipeg and Selkirk, Manitoba, are used to determine the probability of human presence near transmission line structures, considering various land use types and activities. The research also proposes an empirical equation for the probability of ventricular fibrillation based on the body current and fault duration, providing a comprehensive relationship for risk evaluation. The proposed PRA method provides a valuable tool for electric utilities to evaluate and mitigate risks to the public near transmission lines. Our research findings using the PRA method have already been shared with the Canadian Standards Association (CSA) to contribute to the development of a new standard C22.3 No.2 for transmission and distribution grounding in Canada, addressing the public safety concerns associated with transmission lines. The second part of the research investigates corrosion of transmission line tower foundations caused by DC stray currents from adjacent facilities, such as underground pipelines or electrified railways. This is a significant concern as shared right-of-ways (ROWs) between transmission lines and pipelines or railways become more common, leading to stray current interactions and accelerated corrosion. This research firstly focuses on underground pipeline co-location at ROWs. Our research proposes two numerical modeling techniques to model corrosion caused by DC stray current from adjacent pipelines' cathodic protection: the boundary element method (BEM) in the software COMSOL and a direct solution of Maxwell's equations in the software CDEGS (Current Distribution, Electromagnetic Fields, Grounding and Soil Structure Analysis). Following the same methodology, the CDEGS model has been developed to investigate the DC corrosion issue from the electrified railway to the foundation of adjacent transmission line structures. The proposed models were validated using field measurements conducted along an actual co-location ROW. For pipeline, the findings highlight the importance of accurately accounting for coating efficiency in the models and emphasize the need to adjust model parameters based on field-measured data for accurate corrosion predictions. For the railway, the locomotive current and ballast resistance are the governing factors. The investigation of DC stray current corrosion and the development of numerical models offer insights into locating and mitigating corrosion and ensuring the long-term integrity of transmission line structures. This research contributes to a deeper understanding of safety risks associated with transmission line grounding systems on both public and asset safety.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Electrical Engineering
Department thesis:degree_department
Electrical and Computer Engineering
Grantor
University of Saskatchewan
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wang, Chen
Advisor dc:contributor.advisor
  • Liang, Xiaodong
Committee members dc:contributor.committeemember
  • Bedeer Mohamed, Ebrahim
  • Faried, Sherif
  • Wu, Fangxiang
  • Liu, Shichao
  • Karki, Rajesh
ORCID person:identifier.orcid

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/17290

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation