Directional Sub-Cycle Fault Detection On Systems Containing Inverter-Based Resources

Abstract

dc:description.abstract

Renewable energy is quickly becoming a major source of electrical power across the world. As more renewable energy sources are added to the power system, problems have arisen in the protective systems due to these new types of power sources. Some renewable energy sources known as Inverter Based Resources (IBR) interface to the greater power system through inverters, the two main types being Type IV Induction Generators (IG), and Photo-Voltaic (PV) sources. The fault characteristics of these sources are much different than the short circuit current that is generated from traditional sources. This different response to faults may cause traditional protection schemes to fail in detecting when a fault is present, thus leading the demand to find new ways to maintain proper protection of the power system with these new types of sources added. The original research in this document focuses on the protection of power systems when IBR sources are added. The fault current produced by an IBR is markedly different than the fault current traditional sources produce, both in fault current magnitude and composition. IBR fault current have a much lower magnitude, typically in the range of 1.2 - 1.5 per unit (p.u.), in comparison to the 3-10 p.u. magnitude fault current traditional sources may produce. As the addition of IBR sources can cause over-current and negative sequence current based protection schemes to fail, there is a clear and present need for new protection techniques to ensure proper protection when IBRs are added. This thesis discusses the research behind two proposed techniques for protection of IBR systems. The first being through the use of zero sequence current to determine the presence and relative location of asymmetrical ground faults. Secondly, a technique that uses an analysis of the Lissajous curves traced by the three phase currents measured at two different points on the system to determine the presence and direction of faults on the system. Finally the hardware implementation of these protection schemes is shown on the Cyclone IV-E FPGA, with a wide range of testing results shown. Zero sequence current is generated when there is an imbalance in a three phase circuit, due to different loading on each phase, or as the result of an asymmetrical ground fault. A path for the zero sequence current to flow is also required, which is not present in all transformer configurations. A protection scheme involving classical methods using zero sequence was current was developed in PSCAD X4 (v4.6). The protection scheme proposed allows directional sub-cycle fault detection asymmetrical ground faults through analysis of the zero sequence current while improved detection times and efficiency are achieved using Least Error Squared Phasor estimation. The scheme monitors the current from the IBR source that is in-feeding into the power system, as well as the current flowing from the traditional source. When an asymmetrical ground fault occurs, zero sequence current will begin to flow, and once it surpasses the set-point, the protection algorithm begins to initiate a trip. The location of the fault relative to the measurement points is able to be determined through the measurement of the phase angle of the zero sequence fault current. The fault direction is then determined to be forward or reverse of the measurement bus, and initiates trips to allow as much of the system as possible to remain intact while removing the fault. Further optimization of this scheme was done using Least Error Squares (LES) phasor estimation. Extensive testing through EMT simulation is done with both five and seven sample windows (with the system being sampled at 720 Hz or 12 Samples per Cycle), and sub-cycle fault detection for asymmetrical ground faults both forward and reverse of the measurement points was achieved. Next, the development of a more robust protection scheme for power systems with IBR is developed using the analysis of Lissajous curves that are traced using current measurements from the power system and the in-feeding IBR source. This scheme allows directional sub-cycle fault detection without the limitation of requiring a grounded transformer present as was the case in the zero sequence based protection scheme. Both low and high impedance (up to 100 Ohms) faults are able to be detected with this scheme. The two sets of currents are plotted on a Cartesian plane, with the grid current measurements providing the y coordinate of a point on the plane and the x coordinate taken from the IBR current measured at the same point in time. These currents are again sampled at a rate of 720Hz, giving 12 Samples per Cycle on the 60Hz system. As measurements are made, they are plotted to generate a Lissajous curve consisting of the 12 newest samples of each phase. During steady state operation an ellipse will be traced with the angle of orientation corresponding to the phase shift between the measured currents. The area enclosed by the Lissajous curve, in addition to the orientation of the shape it traces are monitored by the protection scheme. When a fault occurs, the shape traced by the Lissajous curve can change rapidly, the area enclosed by the curve generally increases and the orientation of the shape will change. These two elements form the basis of protection scheme, essentially the area enclosed by the Lissajous curve is monitored, and once a significant change is found, the change in orientation of the shape is determined and a direction for the fault location is able to be made. Testing of the algorithm is performed on a wide variety of fault conditions, including fault location, fault type, fault time, fault impedance, and transformer configuration, leading to 576 unique cases being tested successfully. These protection schemes are implemented in hardware on an Intel Cyclone IV-E FPGA using Verilog HDL. The measurements from the EMT simulations are fed into the FPGA to allow testing of the same scenarios used in the simulation based testing. The hardware testing results mirrored the EMT simulation results, the detection times increasing slightly as a result of the overhead from the Verilog HDL instructions. With the zero sequence protection scheme, sub-cycle fault detection was still achieved in all the test cases however. The Lissajous curve based protection fault detection scheme was also implemented on an Intel Cyclone IV-E FPGA in order to verify the operation of the scheme outside of EMT simulations. All 576 test cases from the PSCAD-EMTDC X4 simulations were tested successfully on the FPGA implementation, with results being shown in oscilloscope trace captures demonstrating the sub-cycle fault detection for power systems containing IBRs.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Electrical Engineering
Department thesis:degree_department
Electrical and Computer Engineering
Grantor
University of Saskatchewan
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pannell, Jason B
Advisor dc:contributor.advisor
  • Gokaraju, Ramkrishna
Committee members dc:contributor.committeemember
  • Fan, Lingling
  • Boulfiza, Moh
  • Liang, Xiaodong
  • Berscheid, Brian
  • Faried, Sherif
  • Mehr, Aryan
ORCID person:identifier.orcid

Subjects

dc:subject × 3

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/17654

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Pannell, Jason B. Directional Sub-Cycle Fault Detection On Systems Containing Inverter-Based Resources. Doctoral thesis, University of Saskatchewan, 2025. https://hdl.handle.net/10388/17654