Abstract
dc:description.abstractGlobally, buildings account for 40% of total energy consumption and 33% of total greenhouse gas (GHG) emissions. In cold climates such as Canada, space heating systems are primarily responsible for energy consumption and GHG emissions in buildings. Using gas absorption heat pumps (GAHPs) instead of natural gas (NG) furnaces, which are commonly used for space heating in many parts of Canada, is expected to reduce heating energy consumption and GHG emissions. The main goal of this thesis is to determine whether GAHPs are feasible to be used for space heating and cooling in cold climates, including the effects of frosting. The feasibility of GAHPs is assessed by comparing the energy consumption, fuel cost and GHG emissions of a GAHP with that of a NG furnace and an electric air-source heat pump (electric ASHP). Comparisons are included for heating only and for combined heating and cooling. To compare the GAHP with other space heating equipment, a small office building is modelled and simulated using eQUEST and hourly weather data of several Canadian cities. A thermodynamic model of the GAHP is then used to estimate energy consumption, fuel cost and GHG emissions in each city, and these values are compared to the values obtained with other space heating and cooling equipment. This thesis shows that GAHPs may be a feasible option in some cold climate cities and that frosting has a negligible impact on GAHP performance. During heating operation, a GAHP has lower energy consumption and GHG emissions compared to a typical high efficiency NG furnace in all cities investigated. A GAHP has higher combined heating and cooling energy consumption than an electric ASHP. On the other hand, a GAHP may have lower cost and GHG emissions compared to an electric ASHP depending on the local climate, ratio of electricity to NG fuel costs, and GHG emission intensity of the electric grid. In two of the nine Canadian cities investigated (Vancouver and Montreal), the GAHP has higher fuel costs compared to an electric ASHP because the cost of electricity is low compared to the cost of NG in these cities. In two of the nine cities (Saskatoon and Edmonton), the GAHP has lower GHG emissions because the emission intensity of the electric grid is high in these cities. The thesis also develops a method to predict if a GAHP will have lower fuel cost and GHG emissions compared to an electric ASHP in other cities without detailed simulation.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (M.Sc.)
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department thesis:degree_department
- Mechanical Engineering
- Grantor
- University of Saskatchewan
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Sayeed, Tahmid Ibn
- Advisors dc:contributor.advisor
-
- Simonson, Carey
- Payan, Samira
- Committee members dc:contributor.committeemember
-
- Bugg, Jim
- Peters, Reisha
- ORCID person:identifier.orcid
Subjects
dc:subject × 4Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10388/17656