University of Saskatchewan
Fabrication Of Label-Free Detectors Based On Resistive Pulses Across High Aspect Ratio Artificial Nanopores In Multilayer Composite Thin Membranes
Abstract
dc:description.abstractResistive pulse sensing (RPS) is a label-free detection technique to identify individual molecules by monitoring transient changes in ionic current as the molecules translocate between two electrolyte reservoirs through a nanoscale pore. While RPS is widely applied to detect and characterize biomolecules such as DNA and proteins, limitations in selectivity, signal duration, and fabrication precision remain areas for improvement. Conventional RPS systems rely on fleeting current blockages, making detection susceptible to signal loss and challenging discrimination between structurally similar molecules. This research introduces an advanced RPS-based sensing approach that combines electrophoretic translocation with an antibody-functionalized nanopore to obtain specific and quasi-permanent signals. Target biomolecules are captured by antibodies permanently immobilized on the inner walls of the pore, producing a stable current blockage signal without the need for sample labelling. Proving the concept of such devices required addressing diverse fabrication challenges: High aspect ratio and material-independent patterning of 80 nm wide nanopores across a multi-material composite membrane of 500 nm thickness, or pore length, was accomplished by developing a process for focused ion beam (FIB) sculpting using 30 kV gallium ions. The composite membrane was composed of a 100 nm gold thin film between two PMMA cladding layers. Processing on a copper sacrificial layer enabled gentle membrane release after nanopatterning. Inside the nanopore, the exposed sidewalls of the core gold layer were activated with thiols. Primary antibodies (6x-His Tag Monoclonal Antibody MA1-21315) were immobilized on only the activated layer by adapting protocols commonly used in biochemistry to the size and geometric restrictions inside a nanopore. Numerical simulations were performed to identify the impact of fabrication artifacts on device performance, and to incorporate that understanding into the device design. Two fully functionalized RPS devices were tested and characterized with respect to their open-pore current and current blockage upon delivery of secondary antibodies as the particles of interest. The hypothesis was proven that these secondary antibodies bind to the primary antibodies inside the nanopore, and that, upon delivery, a reduction in the baseline RPS current occurs due to increased and quasi-permanent current blockage. Such an increase in pore resistance, and hence reduction in current, was detected as an overall change for both devices tested. A reduction to about 50% to 65% of the initial open-pore current, or baseline current, was observed and found to be in accordance with the theoretically derived change in pore diameter after the capture of these target agents. This demonstrates a novel implementation of, and approach to, resistive pulse sensing, offering a potentially molecule-specific and permanent signal.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (Ph.D.)
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Electrical Engineering
- Department thesis:degree_department
- Electrical and Computer Engineering
- Grantor
- University of Saskatchewan
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Berkenbrock, Jose Alvim
- Committee members dc:contributor.committeemember
-
- Eames, Brian
- Klymyshyn, David
- Maw, Sean
- Stoeber, Boris
- Gokaraju, Rama
- ORCID person:identifier.orcid
Subjects
dc:subject × 4Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10388/18034