University of Saskatchewan
Weather-Based Dynamic Line and Transformer Rating for Transmission Adequacy Assessment in Power Systems
Abstract
dc:description.abstractTransmission systems are facing increasing pressure from electrification, changing demand patterns, and the need to use existing infrastructure more efficiently. Under these conditions, conventional static thermal ratings may provide an overly conservative representation of transmission asset capability, since they do not reflect the actual time-varying effects of weather and loading on overhead lines and transformers. Dynamic rating provides an alternative by estimating asset capacity as a function of operating conditions rather than by relying on fixed benchmark values. Dynamic Line Rating (DLR) considers the influence of ambient temperature, wind speed, wind direction, and solar heating on the thermal behaviour of overhead conductors. Dynamic Transformer Rating (DTR) similarly relies on thermal assessment of transformer top-oil and hottest-spot temperatures, which vary with ambient temperature and loading history. In this thesis, DLR and DTR are studied together within a common transmission adequacy framework. The work combines an IEEE 738-based line model with an IEEE C57.91-based transformer model, where the transformer is evaluated through both steady-state dynamic capacity and transient thermal-aging response. The main contribution of the thesis is an integrated, planning-oriented framework that evaluates weather-responsive line capability, weather-responsive transformer capability, synthetic weather uncertainty, stochastic load uncertainty, and transformer aging within one hourly adequacy workflow. The framework is applied using hourly weather, load, and asset parameter data. In addition to a single-year deterministic analysis, the thesis includes a multi-year comparison across 2021–2025 and a probabilistic adequacy analysis based on synthetic weather scenarios and stochastic load perturbations. Four adequacy cases are examined: Static, DLR-only, DTR-only, and Combined. The results show that both DLR and DTR reveal additional capacity relative to static benchmark ratings, while the combined application of line and transformer dynamic ratings provides the greatest reduction in overload risk. The results also show that transformer flexibility should be interpreted together with hotspot temperature and cumulative loss-of-life rather than as a purely capacity-based benefit. Overall, the thesis demonstrates that transmission adequacy is governed by the interaction of line and transformer constraints, and that dynamic rating provides a more realistic basis for adequacy assessment than static thermal assumptions alone.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (M.Sc.)
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Electrical Engineering
- Department thesis:degree_department
- Electrical and Computer Engineering
- Grantor
- University of Saskatchewan
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Huang, Ziyan
- Advisor dc:contributor.advisor
-
- Gokaraju, Ramakrishna
- Committee member dc:contributor.committeemember
-
- Farid, Sherif
Subjects
dc:subject × 3Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10388/18400