Back to search

University of Saskatchewan

Transmit Coil Decoupling for Transmit Array Spatial Encoding Magnetic Resonance Imaging

Abstract

dc:description.abstract

Advancements in Magnetic Resonance Imaging (MRI) over the years have led to innovations in design and an increase in MRI application. One such innovation is the development of the Transmit Array Spatial Encoding (TRASE) method for acquiring MRI images, which makes use of a spatial phase gradient in the transmitted radio frequency (RF) magnetic field to encode imaging information. By encoding images in this way, TRASE MRI designs no longer need the gradient coils of traditional MRIs, making TRASE MRIs ideal for portable and low-field MRI designs. TRASE MRIs have previously been constrained due to the inductive coupling which occurs between their RF coils used during imaging, which in turn causes problems for image acquisition. Various solutions to this problem have been proposed and each solution has been met with varying degrees of success. Here, an RF switch solution is investigated. The work presented in this thesis outlines the design, development, implementation, and testing of an active electronic RF switch for the TRASE RF coils of a low-field, 60 mT TRASE MRI, the “Merlin MRI”, previously used for testing in zero-gravity. Influenced by the successful design by others of an active PIN-diode-based RF switch used for TRASE imaging at 200 mT, the RF trap circuit switch presented in this thesis went through two iterations of completed designs. Both designs made use of off-the-shelf transistor-based RF switch circuit components and adapted the switches for use within TRASE MRIs. Initial integration of the RF trap circuit switches with the Merlin MRI coils found that an open-circuit reflective RF switch cannot meet the constraints required for implementation with TRASE MRIs. After performing numerical simulations, it was found that a short-circuit reflective RF switch would be required to make the RF trap circuit switch viable. Incorporating such a switch into the design of the RF trap circuit switch then led to testing that was representative of conditions that would take place during imaging with a TRASE MRI. The RF trap circuit switch, when using the short-circuit reflective RF switch integrated circuit, was found to be successful in isolating the Merlin MRI’s RF coils from one another and could switch at speeds required for TRASE imaging. However, when attempting to transmit the high RF power required during imaging, the RF trap circuit switch failed to handle the power. Recommendations are given for the proposed next steps in the development of the RF trap circuit switch.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Physics
Department thesis:degree_department
Physics and Engineering Physics
Grantor
University of Saskatchewan
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hogue, Micheal
Advisor dc:contributor.advisor
  • Sarty, Gordon E
Committee members dc:contributor.committeemember
  • Hussey, Glenn
  • Boland, Mark

Subjects

dc:subject × 4

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/19052

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Hogue, Micheal. Transmit Coil Decoupling for Transmit Array Spatial Encoding Magnetic Resonance Imaging. Masters thesis, University of Saskatchewan, 2026. https://hdl.handle.net/10388/19052