Back to search

University of Saskatchewan

Development and Characterization of a Fabrication Process for X-Ray Lithography Masks Based on a Silicon Nitride Membrane

Abstract

dc:description.abstract

A novel X-ray lithography (XRL) mask concept and fabrication approach is developed, tested, and validated. The concept focusses on yielding high-quality, low-cost intermediate masks, suitable for patterning devices with resist thickness of up to tens of micrometers. Specific consideration was given to meet the needs and exploit the capabilities of the Synchrotron Laboratory for Micro and Nano Devices (SyLMAND) at the Canadian Light Source (CLS). The developed X-ray mask concept is based on commercially available, nitride-coated silicon wafers to ensure reliability and to minimize material costs. An electroplating seed layer of 1.5 µm thick TiO1.9 and a photoresist layer of 5 µm thick SU-8 are deposited onto the 2 µm thick silicon nitride that coats the sacrificial silicon wafer. The resist layer is lithographically patterned using the in-house direct write UV laser lithography system for fast turn-around, good process control, and affordability. 3 µm of gold are subsequently electroplated into the resist voids to form the mask absorbers. In a final step, all but the perimeter of the silicon wafer is wet chemically etched away, delivering a suspended and X-ray transparent silicon nitride membrane. The silicon wafer perimeter is further supported by a glued-on aluminum frame for ease of handling and to interface with beamline hardware. The concept was developed iteratively, adjusting material selection and methodologies based on existing literature and experimental results. The resulting process was successfully demonstrated to produce two mask demonstrators. The mask demonstrators were characterized directly through inspection of the masks themselves and indirectly through inspection of test samples produced by using the masks in XRL exposures at SyLMAND. In both direct and indirect inspection, the mask demonstrators exhibited sufficient quality for typical applications of XRL at SyLMAND. Sidewalls of absorbers and of exposed samples are generally smooth and vertical. Minimum features sizes are layout dependent and allow for structural details down to one micrometer. The feature size accuracy between mask and sample is 2.0 µm or less under optimal conditions, and positional inaccuracy is limited to a fraction of a micrometer per millimeter of nominal distance. Thermal distortions are well controlled and consistent with above limitations. The mask membranes are durable and effectively free of warp. The mask contrast is sufficiently high to process the full range of targeted sample applications.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Electrical Engineering
Department thesis:degree_department
Electrical and Computer Engineering
Grantor
University of Saskatchewan
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zanyk, Noah
Advisor dc:contributor.advisor
  • Achenbach, Sven
Committee members dc:contributor.committeemember
  • Achenbach, Sven
  • Behzad, Nouri

Subjects

dc:subject × 3

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/19217

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Zanyk, Noah. Development and Characterization of a Fabrication Process for X-Ray Lithography Masks Based on a Silicon Nitride Membrane. Masters thesis, University of Saskatchewan, 2026. https://hdl.handle.net/10388/19217