The goal of this study was the dosimetric characterization of a mini-beam collimator on three clinically beam matched Varian iX linear accelerators. Measurements of the beam quality (%DD(10)), peak-to-valley dose ratio (PVDR), collimator factor (CF), and relative output factor (OF) were carried out for 2 cm x 2 cm, 3 cm x 3 cm, 4 cm x 4 cm, and 5 cm x 5 cm mini-beam collimated 6 MV fields on each linear accelerator. As well, Monte Carlo simulation of the mini-beam collimated fields were used to link the measurement results to a validated linear accelerator model. The quality of the mini-beam collimated field was clinically equivalent to that of the open field. Changes in the mini-beam collimated field in response to changes in both field size and collimator inclination were consistent across all three linear accelerators. However, PVDR, collimator factors, and relative output factors varied in excess of the measurement uncertainty, revealing a difference in the mini-beam collimated fields of each linear accelerator. The change in PVDR was proportional to that of the collimator factor and relative output factor. The Monte Carlo simulations showed that variation in the full-width half-maximum of the linear accelerators’ electron beam incident on the Bremsstrahlung target correlated to the variation in collimator factor and PVDR across the accelerators. These results demonstrate that while the mini-beam collimated field varies across linear accelerators, the effect can be accounted for in the linear accelerator model, allowing the planning and delivery of mini-beam collimated fields using medical linear accelerators.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Physics
Department thesis:degree_department
Physics and Engineering Physics
Grantor
University of Saskatchewan
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Davis, William M 1992-
Advisors dc:contributor.advisor
  • Rangacharyulu, Chary
  • Cranmer-Sargison, Gavin
Committee members dc:contributor.committeemember
  • Zhang, Chris
  • Yao, Yansun
  • Ghezelbash, Masoud
  • Dick, Rainer
ORCID person:identifier.orcid

Subjects

dc:subject × 4

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/7673

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Davis, William M 1992-. Dosimetric Tranferability of a Medical Linear Accelerator Mounted Mini-Beam Collimator. Masters thesis, University of Saskatchewan, 2017. https://hdl.handle.net/10388/7673