Back to search

University of Saskatchewan

REALIZATION OF A CANINE POSITIONING DEVICE FOR IN SITU PROSTATE PHASE CONTRAST – COMPUTED TOMOGRAPHY IMAGING

Abstract

dc:description.abstract

Background: Worldwide, prostate cancer (PCa) is the most commonly diagnosed non-skin cancer in men. The current diagnostic standard of PCa requires invasive procedures such as needle biopsies. Non-invasive medical imaging techniques, such as Computed Tomography (CT), are only used as an adjunct for staging PCa. The development of a novel non-invasive imaging technique for PCa could revolutionize diagnostic standards and improve patient prognosis. The similarity between canine and human prostates, as well as similar PCa pathophysiology, makes the dog an ideal model for human PCa research. Initial investigations with Phase Contrast – CT (PC-CT) has shown potential for detecting morphological abnormalities in ex vivo canine prostates and therefore warrants further testing as a potential PCa diagnostic imaging technique. This research addresses the design, development and implementation of a canine positioning device used for in situ prostate PC-CT imaging on the Biomedical Imaging and Therapy –Insertion Device Beamline at the Canadian Light Source. This device is currently being used to collect micron-level resolution PC-CT reconstructions of canine cadaver prostates. This thesis lays the ground work for canine imaging on the BMIT – ID beamline at the CLS. The design and implementation of the device are described, along with the issues discovered and addressed.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Biological Engineering
Department thesis:degree_department
Biomedical Engineering
Grantor
University of Saskatchewan
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Keith, Jay D 1992-
Advisors dc:contributor.advisor
  • Pettitt, Murray
  • Snead, Elisabeth
Committee members dc:contributor.committeemember
  • Pettitt, Murray
  • Snead, Elisabeth
  • Singh, Jaswant
  • Chapman, Dean L
  • Gray, Jack
ORCID person:identifier.orcid

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/7846

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Keith, Jay D 1992-. REALIZATION OF A CANINE POSITIONING DEVICE FOR IN SITU PROSTATE PHASE CONTRAST – COMPUTED TOMOGRAPHY IMAGING. Masters thesis, University of Saskatchewan, 2017. https://hdl.handle.net/10388/7846