Back to search

South Dakota State University

Compaction Testing of Granular Material

Abstract

dc:description.abstract

The South Dakota Department of Transportation SDDOT uses the Ohio Highway Department’s Typical Moisture Density Curves for preforming compaction quality control on granular soil materials in junction with standard moisture density relations. The SDDOT also uses the Nuclear Density Gauge NDG, Sand Cone, and Rubber Balloon methods to conduct in-situ density tests. Compaction quality control of recycled pavements is conducted using test strips. The test strip method works well for large areas but becomes problematic for small areas. The ODOT Materials Manual states “Moisture-Density proctor curves and controls were originally developed to be used on cohesive (clays and silts) soils. Errors or complications arise when trying to extrapolate these principals to granular materials” (ODOT, 1998). The SDDOT has also been using more materials recycled from PCC pavements and asphalt concrete pavements as subbase and base courses. For these reasons the SDDOT wishes to reevaluate its current methods compaction quality control of granular materials. A research synthesis report published by the National Cooperative Highway Research Program (NCHRP) has summarized alternative methods used by other DOTs for compaction quality control of granular materials (Nazzal, 2014). The research presented within this report includes the development of a new family of curves for SDDOT encountered base and subbase granular materials and also recommends Dynamic Cone Penetrometer (DCP) methods for compaction quality control of granular materials. The research conducted included a literature review of various alternative forms of granular compaction quality control and analysis of the adequacy of using families of moisture density curves for granular compaction of base and subbase granular materials encountered by the SDDOT. The results of the research indicated that the currently used Ohio Highway Department’s Typical Moisture Density Curves may be over predicting the maximum dry unit weight of base and subbase materials encountered by the SDDOT. The results of an alternatives analysis also indicated that the DCP device may be the best alternative in-situ compaction testing device to meet the needs of the SDDOT.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis - Open Access
Discipline thesis:degree_discipline
Civil and Environmental Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Weber, Jason Jerome
Contributors dc:contributor
  • Allen L Jones

Subjects

dc:subject × 2

Rights

dc:rights
Language dc:language
en

Identifiers

dc:identifier.*
Repository record dc:identifier
https://openprairie.sdstate.edu/etd/2488

Chain of custody

source
Harvested from
South Dakota State University
Base URL
openprairie.sdstate.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Weber, Jason Jerome. Compaction Testing of Granular Material. Thesis - Open Access thesis, https://openprairie.sdstate.edu/etd/2488