Back to search

South Dakota State University

Radiometric Calibration and Uncertainty Analysis of Landsat MSS Sensors Using a Radiance Based Approach on Pseudo-Invariant Calibration Sites

Abstract

dc:description.abstract

The primary objective of this project was to develop a consistent radiometric calibration for the five Landsat Multispectral Scanner (MSS) instruments in terms of producing comparably calibrated Top of Atmosphere (TOA) radiance values. This calibration process will allow the entire MSS data set, as contained within the USGS archive, to be accessed based upon a consistent radiometric scale. Initially, a consistent cross-calibration of all MSS sensors was achieved using co-incident/near co-incident scene pairs as acquired during the spatial and temporal overlap of these satellites sensors. Next, several sets of two nearly co-incident scenes were matched based on use of Pseudo-Invariant Calibration Sites (PICS). Regions of interest were sampled to estimate the relationship between the gains of the two sensors. The cross-calibration to Landsat-5 MSS for each sensor was calculated by combining the results of individual cross-calibrations between sensor pairs. For each sensor, changes in both bias and gain were measured and statistically evaluated. An example of the significance of the results is seen in MSS bands 1 and 2 where prior to calibration sensors exhibit errors up to 16% and 17% respectively. Additionally, temporal shifts (often considered as 'sensor degradation') can modify calibration up to 1% for band 1 and 2% for band 2 over a degradation') can modify calibration up to 1% for band 1 and 2% for band 2 over a sensor's lifetime. Once these calibration parameters are applied, test scenes as sampled from the entire MSS data archive are radiometrically consistent to within 1% for band 1, 2% for band 2, 3% for band 3 and 5% for band 4. Once the cross-calibration connection has been established for a pair of Landsat MSS sensors, the possible uncertainty and ranking of the uncertainty types associated with the cross-calibration process was studied. An error analysis shows that the dominant uncertainty for the cross-calibration was associated with atmospheric uncertainty in nearly coincident scene pairs. Calibration uncertainties range from 4% to 11 % due to the atmosphere; bidirectional reflectance distribution function (BRDF) and filter spectral effects together can add an additional 2% uncertainty.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis - University Access Only
Discipline thesis:degree_discipline
Electrical Engineering and Computer Science

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Karki, Sadhana

Identifiers

dc:identifier.*
Repository record dc:identifier
https://openprairie.sdstate.edu/etd2/1804

Chain of custody

source
Harvested from
South Dakota State University
Base URL
openprairie.sdstate.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Karki, Sadhana. Radiometric Calibration and Uncertainty Analysis of Landsat MSS Sensors Using a Radiance Based Approach on Pseudo-Invariant Calibration Sites. Thesis - University Access Only thesis, https://openprairie.sdstate.edu/etd2/1804