Técnicas de detección y control de faltas para convertidores de potencia de sistemas de generación distribuida
Abstract
dc:description.abstractElectric power is typically produced at a wide range of generation plants. In particular, the renewable energies are a specific electric power generation type. Due to its nature, this technology is possible only where the appropriate conditions happen. Currently, the growth on renewable energies technology development has led to an increment in its penetration factor. Therefore, the electric power grid classic concept with big centralized generation plants is not valid anymore. Moreover, the electric power grids worldwide are changing their centralized models to distributed generation models. By the way, improvement on the renewable energies development has led to a significant growth on the new plants size. Previous cited two factors have obliged to the utility grid to modify the international legislation, adding new minimum technical requirements for the new scenario. The link between the renewable energy plants and the electric power grid usually is done with electronic power converters; therefore they are in charge to comply with the current legislation. Some of the most important requirements are those related to the plant behaviour against several types of grid faults. The objective of this work is the development of power converters control techniques to improve the units response against the specified minimum technical requirements defined in the international legislation. In one hand, due to renewable energy plants usually are near the consumption centres, the detection of possible islanding cases is very important in these plants. An islanding case happens when a part of the electric grid is disconnected, and the resulting subgrid remains energized because the working conditions do not change significantly. Therefore, a new anti-islanding method has been developed to improve significantly the unit response compared with others presented in the literature. Between the advantages of the new method are: it works under any operation set-point; adds fewer perturbations to the system than others; its non-detection-zone is null; and it has a good clearing time behaviour for all islanding cases. On the other hand, the power converters control against transient voltage faults has been described widely in the literature. Most part of research efforts in this phenomenon is centred on the control during the fault itself. However, the beginning of the transient voltage fault usually is faster than the control system frequency, so a possible instability case could happened. As a result, an unexpected output peak current up the security thresholds would be produced. According to this difficulty, a new method has been developed to prevent and control that the output current security thresholds are not reached, avoiding breakdowns and not desired disconnections.
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Muñoz-Cruzado Alba, Jesús
- Advisors dc:contributor.advisor
-
- Galván Díez, Eduardo
- Carrasco Solís, Juan Manuel
Subjects
dc:subject × 4Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Attribution-NonCommercial-NoDerivatives 4.0 Internacional
- Licence dc:rights.uri
- Language dc:language.iso
- spa
Identifiers
dc:identifier.*- Mods Identifier Ror
- https://ror.org/03yxnpp24