University of Southampton
Repetitive current control of two-level and interleaved three-phase PWM utility connected converters
Abstract
dc:description.abstractThis thesis is mainly concerned with investigations into digital repetitive current control<br/>of two-level and interleaved utility connected PWM converters. The research is<br/>motivated by the relatively poor performance of classical (PI) controllers when the<br/>utility voltage harmonic distortion is high. This is due to the low gain, and poor<br/>disturbance rejection of the PI controller at the utility harmonic frequencies. Repetitive<br/>feedback controllers have the ability to track or reject periodic disturbances, such as<br/>utility harmonics, as they naturally have high gains at the utility voltage harmonic<br/>frequencies, assuming that these frequencies do not change.<br/><br/>Repetitive controllers (RC) are known for being sensitive to variations in system<br/>parameters and disturbance frequency, which in practice renders them either ineffective<br/>or unstable. Another challenge arises from the memory requirements of RC in case of<br/>the absence of even harmonics, which can make its practical implementation difficult<br/>and expensive. In addition, another problem that has not been investigated extensively<br/>in the literature is that the effectiveness of RC is severely limited by the limited<br/>bandwidth of the plant (the utility connected converter and its filter). Theoretical<br/>analysis and simulation results presented in this thesis show that RC could not<br/>effectively reject disturbances at frequencies above the closed loop system bandwidth.<br/>The design of the converter's output filter bandwidth and the values of its components<br/>need to be selected carefully, to enable RC to be used effectively.<br/><br/>The research in this thesis focuses on investigating the practical implementation and<br/>performance limits of two types of repetitive controllers (conventional and oddharmonics),<br/>used for current control of two-level utility connected converter with LCL<br/>output filter. The odd-harmonic repetitive controller halves the memory requirement<br/>and offers higher gains only at odd harmonic frequencies of interest. The overall control<br/>scheme consists of the traditional classical tracking controller with a dual loop feedback<br/>system and RC. The results indicate that the repetitive controller improves the steady<br/>state error and the total harmonic distortion of the output current, provided that the<br/>plant's bandwidth is sufficiently large.<br/><br/>Finally, a repetitive controller for an interleaved utility connected converter has been<br/>designed and investigated in this study. The interleaved converter system has higher<br/>bandwidth than the two-level converter, which improves the effectiveness of RC. It<br/>provides good disturbance rejection compared to classical controllers which results in<br/>low output current THD. The RC was demonstrated to be robust despite uncertainty in<br/>utility impedance, while achieving a fast almost zero error convergence. The proposed<br/>RC has been experimentally implemented using a DSP and the results indicate that the<br/>quality of output current complies with international standards on harmonic limits and<br/>matches simulation results obtained from the Matlab/Simulink model of the system.
Degree
thesis:*- Name dc:type.qualificationname
- Ph.D.
- Level dc:type.qualificationlevel
- doctoral
- Grantor dc:publisher.institution
- University of Southampton
- Year dc:date.issued
- 2012
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Jamil, Mohsin
- Advisor dc:contributor.advisor
-
- Sharkh, S.M.
- ORCID person:identifier.orcid
Rights
- Language dc:language.dcterms_iso639_2
- eng