Back to search

University of Southampton

Analysis of an alternative topology for steel-concrete-steel sandwich beams incorporating inclined shear connectors

Abstract

dc:description.abstract

This thesis presents a new concept in steel-concrete-steel sandwich construction in which a bi-directional corrugated-strip core is proposed as an alternative inclined shear connector. The focus is on the feasibility study of fabrication techniques and the theoretical study of the structural responses of both unfilled and concrete-filled steel-concrete-steel sandwich beams under static flexural loading using numerical and analytical methods. Two possible fabrication techniques to create the proposed bi-directional corrugated strip core are presented. The unfilled sandwich beam is studied using a finite element method and three analytical methods referred to as the modified stiffness matrix, the braced frame analogy, and the discrete beam methods The finite element method is used to investigate the stiffness and strength behaviour of the unfilled sandwich beam.<br/>The modified stiffness matrix method provides good correlation with the finite element method. The other two analytical methods are less accurate. The assessment of the effect of geometrical parameters defining the bi-directional corrugated-strip core is carried out. The responses of the strength and stiffness, especially the transverse shear stiffness, are examined and discussed. The optimum configuration of the core is found at the angle of the inclined part of the corrugation is about 45°. The concrete-filled sandwich beam is studied using the finite element method. The finite element method is used to investigate the transverse shear strength and the crack development of a four-point loaded concrete-filled sandwich beam. The assessment of the effect of geometrical parameters defining the inclined shear connectors is carried out. The responses of the concrete-filled sandwich beam are examined and discussed. The optimum advantage of the transverse shear strength of the concrete-filled sandwich beam is also found when the inclined shear connectors align at an angle 45º. It is found that creating the proposed core with a 45° pattern provides a great advantage in transverse shear stiffness and strength in both the unfilled and concrete-filled sandwich beams.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Leekitwattana, M.
Advisors dc:contributor.advisor
  • Boyd, Stephen W.
  • Shenoi, R.A.

Rights

Language dc:language.dcterms_iso639_2
eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Leekitwattana, M.. Analysis of an alternative topology for steel-concrete-steel sandwich beams incorporating inclined shear connectors. doctoral thesis, University of Southampton, 2011.