Back to search

University of Southampton

Wavelet filter banks for cochlear implants

Abstract

dc:description.abstract

Cochlear implant (CI) users regularly perform as well as normal-hearing (NH) listeners in quiet conditions. However, CI users have reduced speech perception in noise. CI users suffer more in terms of speech intelligibility than NH listeners in the same noisy environment. Speech coding strategies with noise reduction algorithms for CI devices play an important role, allowing CI users to benefit more from their implants. This thesis investigates a wavelet packet-based speech coding strategy with envelope-based noise reduction algorithms to enhance speech intelligibility in noisy conditions.<br/><br/>The advantages of wavelet packet transforms (WPTs), in terms of time-frequency analysis, the sparseness property, and low computational complexity, might make WPT appropriate for speech coding and denoising in CI devices. In cases with an optimal set of parameters for a wavelet packet-based speech coding strategy, the 23- and 64-band WPTs with sym8 and frame length of 8 ms were found to be more suitable than other combinations for this strategy. These parameters can optimise speech intelligibility to benefit CI users. However, both the standard ACE strategy and the wavelet packet-based strategy provided almost the same results in either quiet or noisy conditions.<br/><br/>Cases using envelope-based denoising techniques in a wavelet packet-based strategy, namely time-adaptive wavelet thresholding (TAWT) and time-frequency spectral subtraction (TFSS) were developed and evaluated by objective and subjective intelligibility measures and compared to ideal binary masking (IdBM) as a baseline for denoising performance. IdBM can restore intelligibility to nearly the same level as NH listeners in all noisy conditions. Both TAWT and TFSS showed slight intelligibility improvements in some noisy conditions. This may result from noise estimation in denoising techniques. Noise level may be under- or overestimated, and this results in distortion in enhanced speech and difficult in speech discrimination.<br/><br/>Both objective and subjective intelligibility measures can predict the trend of the performance of different denoising techniques for CI users. However, NH listeners can achieve better intelligibility at higher SNR levels without noise reduction, since they are less sensitive to noise but more sensitive to speech distortion when compared to CI listeners. Therefore, denoising techniques may work well for CI users in further investigations.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dachasilaruk, Siriporn
Advisor dc:contributor.advisor
  • Bleeck, Stefan
ORCID person:identifier.orcid

Rights

Language dc:language
English, eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Dachasilaruk, Siriporn. Wavelet filter banks for cochlear implants. doctoral thesis, University of Southampton, 2014.