Back to search

University of Southampton

An investigation of the factors associated with the X-ray tube and their influence on dimensional measurement in micro-focus cane-beam industrial X-ray computed tomography systems

Abstract

dc:description.abstract

In recent years, X-ray computed tomography (XCT) has successfully entered the field of dimensional metrology. XCT offers advantages over traditional tactile and optical coordinate measuring machines because of its ability to detect both the outer and inner geometries of an object. Due to the complex nature of XCT, there are a large number of factors which can influence dimensional measurement; many of these factors are still poorly understood.<br/>The novel study of a number of influence factors associated with the X-ray tube and their influence on dimensional measurement in micro-focus cone-beam XCT systems is presented in this thesis. The influence factors investigated in this study are the positional stability of the focal spot, the off-focal radiation, the focal spot size and the focal spot shape. The necessary background information to X-ray physics, XCT technology and dimensional metrology is discussed. The analysis of these influence factors was conducted at the National Physical Laboratory using experimental and computer simulation techniques. The experimental part of this research was carried out on Nikon Metrology XT H 225 M, with simulations performed using bespoke computer codes.<br/>The results of the study show that the positional stability of the focal spot, the off-focal radiation, the focal spot size and shape can all affect dimensional measurement. It is, therefore, proposed to include these parameters as part of the future standardised X-ray tube qualification and performance verification procedures of XCT systems. The evaluation techniques developed during the study can be employed as part of these standardised procedures. In addition, based on the findings of the study a number of future areas of research are proposed.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Flay, Nadia
Advisor dc:contributor.advisor
  • Blumensath, Thomas
ORCID person:identifier.orcid

Rights

Language dc:language
English, eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Flay, Nadia. An investigation of the factors associated with the X-ray tube and their influence on dimensional measurement in micro-focus cane-beam industrial X-ray computed tomography systems. doctoral thesis, University of Southampton, 2016.