Back to search

University of Southampton

Clinical application of maximum entropy image processing in planar radionuclide imaging

Abstract

dc:description.abstract

<p>The aim of the research was to develop the technique of maximum entropy for clinical application and to evaluate its effectiveness in improving image quality.</p><p>Maximum entropy (ME) requires definition of various parameters for its operation. Studies were carried out to investigate the way in which the values of these parameters affected image quality. This allows methods for deriving optimal values in any situation to be devised.</p><p>A study was carried out to investigate the way in which the figure of merit (FOM) method of image quality assessment depended on definition of regions defining the object and surroundings. This allowed description of a method for defining the regions which provided robust values for FOM.</p><p>A comparative evaluation of maximum entropy processing with simple image smoothing (i.e. conventional smoothing (SM)) and Wiener filtering (WF) was carried out in simulated images of a planar object. Image quality was evaluated using the FOM and using receiver operating characteristic (ROC) analysis with two different observers. The FOM analysis showed that all image processing technique produced significant improvement over the raw data and that ME was the best of the methods. These findings were generally supported by the ROC analysis although, the conclusions were not so clearly defined. There was significant correlation between FOM and detectability for individual observers interpreting images from a single processing technique. Correlation was poorer when data from all the methods were combined.</p><p>A further comparative evaluation of the processing techniques in simulated lung images was performed using ROC analysis. The analysis failed to show significant improvements in detectability using conventional smoothing or Wiener filtering.</p>

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mattar, Essam Hussain

Rights

Language dc:language
English, eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Mattar, Essam Hussain. Clinical application of maximum entropy image processing in planar radionuclide imaging. doctoral thesis, University of Southampton, 2000.