Back to search

University of Southampton

Non-ferrous compositely reinforced concrete columns

Abstract

dc:description.abstract

<p>The experimental programme investigated the behaviour of 81 stocky concrete-filled E-glass FRP-composite columns subject to nominal eccentric load. The main parameters investigated were concrete strength, orientation of confining fibres, column slenderness and type of longitudinal FRP reinforcement. The experimental study found the greatest enhancement in load capacity was achieved using FRP-composites with fibres oriented in the hoop direction.</p><p>The failure mode of the columns was governed by the type of longitudinal FRP reinforcement. Failure of columns reinforced with additional carbon FRP bars were initiated by the failure of the FRP. Additional E-glass FRP-composite bars as longitudinal reinforcement were found to increase the post-crushing stiffness and the ultimate load capacity of the column. The compressive failure strain of the E-glass reinforcement with triaxial confinement was comparable to the tensile failure strain.</p><p>Second-order effects were found to be more significant at lower slenderness ratios in concrete-filled FRP-composite columns than for conventional R.C. columns. Furthermore, the benefits of FRP-confinement are negligible if the column slenderness ratio is greater than 12.</p><p>The proposed design method for concrete-filled FRP-composite columns uses the CONFINE computer model developed as part of this research. The deflected profile of the column is assumed to be approximated by a part sinusoidal waveform. The CONFINE model gives good correlation with the experimental data for concrete-filled glass FRP-composite columns subjected to small eccentricities of load. The mathematics of the model enables predictions of the deflections, curvature and strains in the columns over the entire load history with a high degree of confidence.</p>

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lillistone, Duncan

Rights

Language dc:language
English, eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Lillistone, Duncan. Non-ferrous compositely reinforced concrete columns. doctoral thesis, University of Southampton, 2000.