Enhanced Accuracy and Precision of Analysis of Selenium in Clinical Matrices

Abstract

dc:description.abstract

<p>Conventional calibration procedures using external standards or standard additions provide sufficient precision and accuracy of selenium concentrations for clinical purposes, but an enhanced quality of analysis is required for accurate analysis of reference materials and for valid comparisons of inter-laboratory studies on a world-wide scale. Isotope Dilution (ID) mass spectrometry, a technique reputed for achieving high accuracy measurements, was investigated to improve the reproducibility and accuracy of selenium determinations by established methods. Low resolution inductively coupled plasma mass spectrometry (ICP-MS) using solution nebulisation (SN) was used for the accurate and precise determination of selenium isotopes. The addition of butan-1-o1 to the samples reduced the interferences normally experienced by direct analysis of selenium in biological matrices, and also enhanced signal response. Samples were spiked with a <sup>74</sup>Se-enriched isotopic standard, and accurate determinations of <sup>78</sup>Se: <sup>74</sup>Se ratios were converted into concentrations, using regression line equations obtained from calibrating solution ratios. This produced significant improvements in precision over conventional (single isotopic) ICP-MS analysis. Between-run relative standard deviations approached those obtained within-run, and were 1.0-6.0% for 0.25 - 1.90 &mu;mol l<sup>-1</sup> selenium. An interlaboratory comparison showed improved accuracy, with a reduced overall spread of bias to 0.0 ± 0.05 &mu;mol l<sup>-1</sup> selenium for ID, compared with -0.01 ± 0.07 &mu;mol 1<sup>-1</sup> for conventional analysis.</p><p>Alternative methodologies/instrumentation for ICP-MS were investigated to establish the degree of accuracy and precision attainable for the measurement of selenium in serum. These techniques were compared to a method developed for conventional standard addition analysis of selenium, in which samples were diluted 1+14 in 0.5% v/v butan -1o1 and the signal at mass 78 monitored. The accuracy of the described method was demonstrated by the laboratory's excellent performance in two External Quality Control Assessment schemes, over 18 months. Hydride generation (HG) was evaluated as a method of sample introduction for ICP-MS. Multi-collector magnetic field (ICP-MC-MS) and Dynamic Reaction Cell (DRC-ICP-MS) instrumentation, which use collision or reaction cells to destabilise any polyatomic argon adducts, were also assessed for their potential to enhance precision in quantitative isotopic analysis. The order of both precision and accuracy of analysis was found to be ID-DRC-ICP-MS &cong; ID-SN- ICP-MS > DRC-ICP-MS &cong; SN-ICP-MS >>HG-ICP-MS.</p>

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sieniawska, Christine Elizabeth

Rights

Language dc:language
English, eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Sieniawska, Christine Elizabeth. Enhanced Accuracy and Precision of Analysis of Selenium in Clinical Matrices. doctoral thesis, University of Southampton, 2001.