Back to search

University of Southampton

Assessing the performance envelope of total knee replacement : an explicit finite element study

Abstract

dc:description.abstract

<p>The purpose of this study was to examine: 1) The performance of TKR for a variety of activities, 2) The performance of TKR under the influence of eccentric loading, 3) The performance envelope of TKR under subject specific loading, and 4) The effect of misalignment on the performance of TKR. Two TKR designs: PFC &Sigma; and PFC PLI knees (DePuy) have been examined in this thesis. Simulations were performed using dynamic finite element method. In the first study, the TKR produced larger kinematics and contact pressures when simulated using more demanding loads from stair descent and squatting activities. Stair ascent and level gait activities were also simulated. Inclusion of other loading activities in wear studies could help in understanding wear observed <i>in vivo</i>. In the 2<sup>nd</sup> study, the influence of varus/valgus knee on the performance of TKR was stimulated by offsetting the point of application of the axial load either medially or laterally. Medial eccentric loading was the most destructive for the TKR particularly when the collateral ligaments were not included. The femoral component rode up the anterior lip of the tibial insert and nearly subluxed. Lateral eccentric loading did not show significant kinematics variations as compared to medial eccentric loading, with or without the collateral ligaments. The femoral component did not ride up the anterior edge of the tibial insert. Both the medial and lateral eccentric loading should be avoided as they increased the contact stresses and would lead to accelerated wear. In the 3<sup>rd</sup> study, the simulations were performed by applying level gait loads obtained from 7 subjects and stair ascent loads from 9 subjects. Performance envelopes in the kinematics and contact pressures were obtained as a result of patient-to-patient variability. The kinematics for the PFC &Sigma; and PLI designs were relatively insensitive to subject specific loading during level gait but greater variations during stair ascent.</p>

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tan, Rachael Kheng Hooi

Rights

Language dc:language
English, eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Tan, Rachael Kheng Hooi. Assessing the performance envelope of total knee replacement : an explicit finite element study. doctoral thesis, University of Southampton, 2004.